WARNING

 – When using electrical appliances, basic safety precautions should 

always be followed to reduce the risk of fire, electric shock, and/or injury to 

persons, including the following:

1.

 Read all instructions.

2.

 This appliance is not intended for use by persons with reduced physical, 

sensory, or mental capabilities, or lack of experience and knowledge, unless they 

are closely supervised and instructed concerning use of the appliance by a person 

responsible for their safety.

3.

 This appliance is not to be used by children. Close supervision is necessary 

when any appliance is used near children. Children should be supervised to ensure 

that they do not play with the appliance.

4

. Never let the vacuum sealer run unattended. Disconnect the vacuum sealer from 

the power source before leaving the work area.

5. 

To protect against risk of electric shock, do not immerse cord, plug, or vacuum 

sealer in water or other liquid.

6.

 To reduce the risk of electric shock and injury to persons, disconnect from power 

supply when not in use, before cleaning and before servicing.

7.

 To provide continued protection against risk, do not operate any appliance with 

a damaged supply cord or plug, or after the appliance malfunctions or has been 

dropped or damaged in any manner. Supply cord replacement and repairs must be 

conducted by the manufacturer, its service agent, or similarly qualified persons in 

order to avoid a hazard. Call the provided customer service number for information 

on examination, repair, or adjustment.

8.

 The use of accessory attachments not recommended by the appliance 

manufacturer may cause injuries.

9.

 Do not use outdoors. Optimal operating temperature range is 65

°

 to 75

°.

10.

 Do not let cord hang over edge of table or counter, or touch hot surfaces, 

including stove.

11. 

Do not disassemble this appliance beyond instructions provided. Doing so may 

result in personal injury.

12.

 Do not place on or near a hot gas or electric burner, or in a heated oven.

13.

 Do not use for other than intended purpose.

14.

 This appliance is designed for a maximum vacuum ON time of 70 seconds and 

a minimum OFF time of 10 seconds between cycles. Stop the appliance and allow it 

to cool to ambient temperature if the appliance has been in use for 45 minutes.

15.

 This appliance is for commercial use only.

Important Safeguards 

Содержание VP680

Страница 1: ...v2018 08 20 v2018 08 20 P680 V 80 VP P680 V 80 VP VP680 USER GUIDE Chamber Vacuum Sealer...

Страница 2: ...tively removes air and extends freshness up to five times longer than traditional methods Our versatile and convenient chamber sealer with its three seal bars can preserve multiple items in one sealin...

Страница 3: ...be added Adding Oil to Vacuum Pump Turn off and unplug machine to prevent electrocution 1 Using VacMaster approved 10W non detergent hydraulic oil fill the enclosed plastic oil bottle 2 Locate the oi...

Страница 4: ...sconnect from power supply when not in use before cleaning and before servicing 7 To provide continued protection against risk do not operate any appliance with a damaged supply cord or plug or after...

Страница 5: ...e vacuum packaging helps prevent this from occurring Delicate foods can be frozen prior to packaging to protect them from getting crushed by the vacuum Use VacMaster Bone Guards to cover an item s sha...

Страница 6: ...s feature is used to keep the lid closed while the machine is in storage DO NOT USE while the machine is operating 2 Control Panel 3 Power Switch 4 Vacuum Chamber 5 Filler Plates Used to occupy space...

Страница 7: ...he sealing time using the UP DOWN Buttons Cooling Illuminates to adjust vacuum time as well as during the cooling process During set up adjust the cooling using the UP DOWN buttons 3 Working Indicator...

Страница 8: ...ved Place catch cup underneath before removing drain bolt 7 Capture oil from pump When oil is completely drained replace and tighten bolt Dispose of old oil properly according to your local and state...

Страница 9: ...not stand over the lid 4 To power ON press I on the power switch 5 To power OFF press O on the power switch Set Up Adjusting the VP680 Timing Controls NOTE All timing adjustments must be made with th...

Страница 10: ...uum Time To increase or decrease the vacuum time press the SET button until VACUUM is illuminated and then use the UP DOWN buttons to adjust the vacuum time accordingly The time setting will display o...

Страница 11: ...move and inspect the pouch Vacuum confirmation Check the quality of the vacuum by looking at the tightness of the pouch and the product Look for air pockets or air leaks If you notice that the product...

Страница 12: ...mes first CO Code This stands for change oil Once complete press Set Up Down all 3 at the same time for 3 seconds This will reset and clear this code Mpa 1 2 3 4 5 Instructions 1 Press the program but...

Страница 13: ...estions for Program Settings The vacuum time can be adjusted to your desired length Suggested vacuum time should be set to 18 20 for liquids powders 35 40 is a good starting point for other products A...

Страница 14: ...t is not limited to soft fruits dried foods chips pasta and pre cooked meals By adding a mixture of Carbon Dioxide and Nitrogen the food will stay fresh longer while keeping its original shape How to...

Страница 15: ...nd free of debris for the vacuum process to be successful Wipe surface of the seal bar lid gasket and the inside of the pouch and try again Vacuum pouch loses vacuum after being sealed Sharp items can...

Страница 16: ...every 6 12 months If the filter looks dirty or saturated in oil it will need to be changed If the filter looks clean it is ok to put back into the pump motor assembly 2 Double Sided Tape Used for adhe...

Страница 17: ...anching or freezing before vacuum packaging helps prevent this from occurring NOTE It is critical that food handling and storage are maintained at low temperatures You can reduce the growth of microor...

Страница 18: ...Lower washer Lid 2 5 979683 Lid Gasket 1 6 979825 Top Bar Tape 1 roll 7 979684 Top Bar Side 2 8 979696 Seal Pad Side 2 9 979685 Top Bar Front 1 10 979686 Seal Pad Front 1 11 Sticker 2 LID ASSEMBLY AR...

Страница 19: ...sure adjustment board 2 18 979255 Microswitch 1 19 979380 Piston Large 11 20 979707 Solenoid Valve 1 Part Part Name Qty 21 O type rubber seal ring 2 22 O type rubber seal ring 1 23 Valve connector 1 2...

Страница 20: ...6 Thread direct connection 1 Part Part Name Qty 27 Vacuum pump pipe joint comes w pump 1 28 979707 Vacuum electromagnetic valve 1 29 External thread right angle pipe connector 2 30 Rectangular pipe jo...

Страница 21: ...l 1000 Box 6x 30723 8 X 12 Vacuum Chamber Pouches 3 Mil 1 000 Box 6x 40751 8 X 12 Re Therm Vacuum Chamber Pouches 3 Mil 1000 Box 6x 30754 8 X 12 Vacuum Chamber Pouches 4 Mil 1000 Box 6x 50720 8 X 12 Z...

Страница 22: ...Pouches 3 Mil 250 Box 2x 30792 18 X 22 Vacuum Chamber Pouches 3 Mil 500 Box 2x 30761 18 X 22 Vacuum Chamber Pouches 4 Mil 500 Box 2x 30740 18 X 28 Vacuum Chamber Pouches 3 Mil 250 Box 2x 30741 20 X 2...

Страница 23: ...It excludes all other express oral or written warranties and all warranties implied by law with respect to the Goods including any warranties or merchantability or fitness for a particular purpose ii...

Страница 24: ...ll Rights Reserved VacMaster is a trademark or registered trademark of ARY Inc in the United States and other countries P O Box 412888 Kansas City MO 64141 VacMasterFresh com 800 821 7849 A Product of...

Отзывы: