background image

12

ARY, Inc.  |  11880 College Blvd Suite 550 Overland Park, KS 66210 |  www.VacMasterFresh.com  |  800-821-7849

VP

680 Chamber Vacuum Sealer

 | 

User Guide

How to Use

Programmable Vacuum Cycle Instructions

This VacMaster chamber vacuum sealer is now equipped with a new 

feature that allows you to program and store up to 10 different seal cycle 

settings. Changing from liquids to solids to delicate items has never 

been easier to get that perfect amount of vacuum and a double seal for 

an additional layer of protection. 

Also included is an oil change alert that, after 250 uses, reminds you to 

change the oil. This reminder is intended to keep your machine in tip-

top shape. As a rule of thumb change your oil at the 250 uses alert or 

after 3 months whichever comes first. 

CO Code - 

This stands for change oil.

Once complete, press "Set" " Up" "Down" (all 3) at the same time for 3 

seconds. This will reset and clear this code.

Mpa

1

2

3

4

5

Instructions

1.  Press the program button        on the right side of the control panel to 

bring up P0 on the LED Display. 

2.  Press the SET button to change your desired vacuum time. Use up or 

down arrows to adjust desired vacuum time. 

3.  Press SET again to change the seal time. Use up or down arrows to 

adjust desired seal time.

4.  Press SET button again to change your cool-down time. Use up or down 

arrows to adjust desired cool-down time. Add at least 1 Second more to 

cooling time over sealing time.

5.  Press SET one last time to save the settings. 

6.  You are now ready to vacuum seal.

7.  To create a new preset, press the program button to change to P1 and 

repeat the process stated above. 

8.  Set up and save up to 10 unique settings.

9.  To change programmed setting, simply press the program button

Содержание VP680

Страница 1: ...v2018 08 20 v2018 08 20 P680 V 80 VP P680 V 80 VP VP680 USER GUIDE Chamber Vacuum Sealer...

Страница 2: ...tively removes air and extends freshness up to five times longer than traditional methods Our versatile and convenient chamber sealer with its three seal bars can preserve multiple items in one sealin...

Страница 3: ...be added Adding Oil to Vacuum Pump Turn off and unplug machine to prevent electrocution 1 Using VacMaster approved 10W non detergent hydraulic oil fill the enclosed plastic oil bottle 2 Locate the oi...

Страница 4: ...sconnect from power supply when not in use before cleaning and before servicing 7 To provide continued protection against risk do not operate any appliance with a damaged supply cord or plug or after...

Страница 5: ...e vacuum packaging helps prevent this from occurring Delicate foods can be frozen prior to packaging to protect them from getting crushed by the vacuum Use VacMaster Bone Guards to cover an item s sha...

Страница 6: ...s feature is used to keep the lid closed while the machine is in storage DO NOT USE while the machine is operating 2 Control Panel 3 Power Switch 4 Vacuum Chamber 5 Filler Plates Used to occupy space...

Страница 7: ...he sealing time using the UP DOWN Buttons Cooling Illuminates to adjust vacuum time as well as during the cooling process During set up adjust the cooling using the UP DOWN buttons 3 Working Indicator...

Страница 8: ...ved Place catch cup underneath before removing drain bolt 7 Capture oil from pump When oil is completely drained replace and tighten bolt Dispose of old oil properly according to your local and state...

Страница 9: ...not stand over the lid 4 To power ON press I on the power switch 5 To power OFF press O on the power switch Set Up Adjusting the VP680 Timing Controls NOTE All timing adjustments must be made with th...

Страница 10: ...uum Time To increase or decrease the vacuum time press the SET button until VACUUM is illuminated and then use the UP DOWN buttons to adjust the vacuum time accordingly The time setting will display o...

Страница 11: ...move and inspect the pouch Vacuum confirmation Check the quality of the vacuum by looking at the tightness of the pouch and the product Look for air pockets or air leaks If you notice that the product...

Страница 12: ...mes first CO Code This stands for change oil Once complete press Set Up Down all 3 at the same time for 3 seconds This will reset and clear this code Mpa 1 2 3 4 5 Instructions 1 Press the program but...

Страница 13: ...estions for Program Settings The vacuum time can be adjusted to your desired length Suggested vacuum time should be set to 18 20 for liquids powders 35 40 is a good starting point for other products A...

Страница 14: ...t is not limited to soft fruits dried foods chips pasta and pre cooked meals By adding a mixture of Carbon Dioxide and Nitrogen the food will stay fresh longer while keeping its original shape How to...

Страница 15: ...nd free of debris for the vacuum process to be successful Wipe surface of the seal bar lid gasket and the inside of the pouch and try again Vacuum pouch loses vacuum after being sealed Sharp items can...

Страница 16: ...every 6 12 months If the filter looks dirty or saturated in oil it will need to be changed If the filter looks clean it is ok to put back into the pump motor assembly 2 Double Sided Tape Used for adhe...

Страница 17: ...anching or freezing before vacuum packaging helps prevent this from occurring NOTE It is critical that food handling and storage are maintained at low temperatures You can reduce the growth of microor...

Страница 18: ...Lower washer Lid 2 5 979683 Lid Gasket 1 6 979825 Top Bar Tape 1 roll 7 979684 Top Bar Side 2 8 979696 Seal Pad Side 2 9 979685 Top Bar Front 1 10 979686 Seal Pad Front 1 11 Sticker 2 LID ASSEMBLY AR...

Страница 19: ...sure adjustment board 2 18 979255 Microswitch 1 19 979380 Piston Large 11 20 979707 Solenoid Valve 1 Part Part Name Qty 21 O type rubber seal ring 2 22 O type rubber seal ring 1 23 Valve connector 1 2...

Страница 20: ...6 Thread direct connection 1 Part Part Name Qty 27 Vacuum pump pipe joint comes w pump 1 28 979707 Vacuum electromagnetic valve 1 29 External thread right angle pipe connector 2 30 Rectangular pipe jo...

Страница 21: ...l 1000 Box 6x 30723 8 X 12 Vacuum Chamber Pouches 3 Mil 1 000 Box 6x 40751 8 X 12 Re Therm Vacuum Chamber Pouches 3 Mil 1000 Box 6x 30754 8 X 12 Vacuum Chamber Pouches 4 Mil 1000 Box 6x 50720 8 X 12 Z...

Страница 22: ...Pouches 3 Mil 250 Box 2x 30792 18 X 22 Vacuum Chamber Pouches 3 Mil 500 Box 2x 30761 18 X 22 Vacuum Chamber Pouches 4 Mil 500 Box 2x 30740 18 X 28 Vacuum Chamber Pouches 3 Mil 250 Box 2x 30741 20 X 2...

Страница 23: ...It excludes all other express oral or written warranties and all warranties implied by law with respect to the Goods including any warranties or merchantability or fitness for a particular purpose ii...

Страница 24: ...ll Rights Reserved VacMaster is a trademark or registered trademark of ARY Inc in the United States and other countries P O Box 412888 Kansas City MO 64141 VacMasterFresh com 800 821 7849 A Product of...

Отзывы: