LIMIT SWITCH SIGNAL
The relay output is used to signal the achievement of the limit
switches of the leaves:
oPn1
The relay output is closed when the leaf 1 is fully open
oPn2
The relay output is closed when both leaves are fully
open
CLoS
The relay output is closed when both leaves are fully
close
NOTE:
if the gate has only one leaf, select the option
oPn1
;
if it has 2 leaves, select the option
oPn2
ELECTRIC BRAKE
The relay output controls the electric brake of the motor, by
opening or closing when the motor is operated.
nA1
the relay output is open when the motor 1 is at rest,
and closed when it is actuated
nC1
the relay output is closed when the motor 1 is at rest,
and open when it is actuated
nA2
the relay output is open when the motor 2 is at rest,
and closed when it is actuated
nC2
the relay output is closed when the motor 2 is at rest,
and open when it is actuated
rEL1
LSW
oPn 1
oPn 2
CLoS
rEL1
FrEn
nA I
nC I
nA 2
nC 2