ENGLISH
- 13 -
FLASHING LIGHT
According to the programmed logic the relay output is activated
in an intermittent manner during the opening and/or closing
stages of the gate.
FLSh
Flashing 1: the relay output is operated intermittently at
2 Hz when the gate is moving, including any pre-flashing
stage prior to departure
FL.PA
Flashing 2: the relay output is operated intermittently at
2 Hz when the gate is moving, during any pre-flashing
stage and with open, paused gate
COURTESY LIGHT
According to the programmed logic the relay is closed when the
control unit receives a START command
CYCL
The relay output is closed when the control unit receives
a START command. When the gate closes the relay
output still remains closed for the set time, then opens.
W.L.
Warning light: indicates the real time status of the gate,
the type of flashing indicates the four possible
conditions:
- GATE STOPPED light off
- GATE PAUSED light steadily on
- GATE OPENING the light flashes slowly (2Hz)
- GATE CLOSING the light flashes quickly (4Hz)
tiM
The relay output is closed when the control unit receives
a START command and opened after the set timer. If
another START command is received during activation,
the timer is reset.
rEL1
FL.PA
FLSh
rEL1
LUCE
CYCL