ENGLISH
- 11 -
PROGRAMMING
Start the programming procedure on the control unit and select
the menu
i.Adi
1.
Select the item
Si
and press
OK
: the display shows
LUX
NOTE
: to display the firmware version of your device, press the
OK
key
2.
Using the keys
h
and
i
select the output (
rEL1
or
rEL2
)
whose operation logic you want to program and press
OK
3.
Using the keys h and i select the parameter you want to
program:
AUX
Auxiliary Channel: the relay output is controlled by a
transmitter stored on channel 4 of the receiver
embedded in the control unit. The relay output can be
programmed with different operation logics
LAM
Flashing light. According to the programmed logic the
relay output is activated in an intermittent manner
during the gate opening / closing / pause stages
LUCE
Courtesy light. According to the programmed logic
the relay is activated when the control unit receives a
START
command
SEM
Semaphore. The relay output is opened or closed
depending on the settings of the various stages of the
operation cycle (gate stopped and closed, gate
opening, gate closing, gate stopped, gate paused)
LSW
Limit switch signal. The relay output is used to signal
the achievement of the limit switches of the leaves.
FrEn
Electric brake. The relay output controls the electric
brake of the motor, by opening or closing when the
motor
is
operated.
4.
After programming the parameters, select the item
SAVE
to
save the settings and the item
ESC
to exit the programming
menu
no
i.Adi
rEL1
LUCE
FrEn
rEL2
SAvE
ESC
LSW
Si
Fv I.0