E
N
G
L
IS
H
47
Pd8 FUNCTION TABLE
DISPLAY DATA
DESCRIPTION
DEFAULT
MEMO
DATA
St.rt
Operation modes
StAn
StAn
- Start inputs from terminal board are disabled
no
- Standard operation
AP.CH
- Separated opening and closing commands
PrES
- Manned operation
oroL
- Timer operation
FrEn
0 ÷ 10
Brake function
0
StoP
STOP input
no
no
- STOP input not available
invE
- STOP command stops the gate: START command starts moving in the opposite
direction
ProS
- STOP command stops the gate: pressing the START command gate continues the
motion
Fot 1
PHOTO 1 input
no
APCh
- Input is available for the connection of the photocell
no
- Not available
Fot 2
PHOTO 2 input
CFCh
CFCh
- Photocell is active in closing and also when the gate is still
no
- Not available
Ch
- Photocell is active during the closing
tESt
Test of safety devices
no
no
- Function not active
Foto
- Test enabled only for photocells
CoSt
- Test enabled only for safety edges
Ft.Co
- Test enabled either for photocells or for safety edges
CoS1
no/Si
Border 1 input (fixed border)
no
CoS2
no/Si
Border 2 input (mobile border)
no
C.WE
no/Si
Enabling WIRELESS edges
no
FC.En
no/Si
End of stroke inputs
Si
ASM
0.5” ÷ t.AP
Anti-skid function
1.0”
no
- Function disabled
SEnS
0 ÷ 10
Obstacle sensor level
0
Cont
Counter viewing
tot
tot.
- Total number of completed cycles (views in thousands or in units)
Man
- Number of cycles before the next request for service (such a number has been
rounded off to hundreds and it can be set up on 1000-step; in case it is set up
on 0, the request will be disabled and no will be viewed)
APPr
Automatic learning of the operation time
no
no
- Function disabled
Go
- Start up of the automatic learning procedure
FinE
End of programming
no
no
- It does not exit from the program menu
Si