3-18
TM-401 User’s Guide
Taper Tab
D292104.6.fm
Taper Tab
The
Taper Tab
allows the user to adjust taper settings by leading them through four
Taper Setup
screens. The first screen of the
Taper Tab
is shown below.
A.
Tab Menu
B.
Tape Settings
C.
Taper Control Buttons
A.
Press any tab in the
Tab Menu
to open that tab window.
B.
Tape Speed is a percentage of the maximum velocity the carrier tape can be
advanced at. It can be set between 1-10.
Tape Pitch
is determined by the carrier
tape selected. Use the
Pitch Setting Guide
on the taper to determine the correct pitch.
Jog Step
sets the distance in millimeters
the carrier tape will move forward or back-
ward each time a Jog button is pressed.
Note:
The
Jog Step
field requires the value to be
entered in the following format: XX.XX. (i.e. 60.00).
C.
The
Jog
buttons in the
Index Settings
section jog the tape forward or backward
along the
Taper Track
.
The
Pocket Advance
button advances the tape one pocket at a time. The speed
at which the tape advances is set in the
Tape Speed
field.
A
B
C
Taper Screen 1
Содержание TM-401
Страница 4: ......
Страница 74: ...3 32 TM 401 User s Guide Run Tab D292104 6 fm ...
Страница 146: ...5 44 TM 403 User s Guide Configure Inspection D292104 16 fm ...
Страница 158: ...6 12 TM 401 User s Guide Preparing to Run a Pre programmed Job D292104 8a fm ...
Страница 188: ...7 30 TM 401 User s Guide Adjusting PSA Seal Quality D292104 9a fm ...
Страница 199: ...Appendix A Sensors Contents Keyence FS N11CVP FS N12CP Sensor Amplifiers A 2 SMC ZSE30 Vacuum Sensor A 4 ...
Страница 204: ...Appendix A Sensors A 6 SMC ZSE30 Vacuum Sensor D292104 11 fm ...
Страница 208: ......
Страница 284: ......
Страница 286: ...Service and Parts Contacts 61053915 fm Page 2 ...
Страница 288: ...TM 401 Document List D292104 15b fm Page 2 ...
Страница 290: ......
Страница 291: ......
Страница 292: ...751 Summit Avenue Mankato MN 56001 507 387 2039 FAX 507 387 2257 www vtekusa com Email info vtekusa com ...