![V-TEK TM-401 Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/v-tek/tm-401/tm-401_user-manual_3086311051.webp)
D292104.6.fm
Job Tab
Chapter 3: Human Machine Interface
3-9
B. Seal
Type
toggles between
PSA
and
Heat
seal, select correct seal type.
C.
The
Set Point
fields for the
Inner
and
Outer Sealer
are used to set the desired
temperature for Heat Seal. Enter the correct value in both fields, then press the
right
Arrow Key
to move to the next
Job Wizard
screen.
Note:
The TM-401 accommodates a wide range of carrier tapes and cover tapes. Set-
tings may vary from one tape product to another. The recommended starting point is 90°
C. The maximum recommended operating temperature is 160° C
.
The temperature for
each seal shoe should be increased or decreased as needed after running a peel force
test.
The fourth
Job Wizard
screen enables or disables the tape
Leader.
A. Leader
State
toggles between
ON ( I )
and
OFF
(O)
.
B.
Pressing
the
Leader Length
field will open a keypad. Type in the desired value,
then press the right
Arrow Key
to move to the next
Job Wizard
screen.
A
B
Job Wizard Step 4
Содержание TM-401
Страница 4: ......
Страница 74: ...3 32 TM 401 User s Guide Run Tab D292104 6 fm ...
Страница 146: ...5 44 TM 403 User s Guide Configure Inspection D292104 16 fm ...
Страница 158: ...6 12 TM 401 User s Guide Preparing to Run a Pre programmed Job D292104 8a fm ...
Страница 188: ...7 30 TM 401 User s Guide Adjusting PSA Seal Quality D292104 9a fm ...
Страница 199: ...Appendix A Sensors Contents Keyence FS N11CVP FS N12CP Sensor Amplifiers A 2 SMC ZSE30 Vacuum Sensor A 4 ...
Страница 204: ...Appendix A Sensors A 6 SMC ZSE30 Vacuum Sensor D292104 11 fm ...
Страница 208: ......
Страница 284: ......
Страница 286: ...Service and Parts Contacts 61053915 fm Page 2 ...
Страница 288: ...TM 401 Document List D292104 15b fm Page 2 ...
Страница 290: ......
Страница 291: ......
Страница 292: ...751 Summit Avenue Mankato MN 56001 507 387 2039 FAX 507 387 2257 www vtekusa com Email info vtekusa com ...