Appendix A: Sensors
A-2
Keyence FS-N11CP & FSN12CP Sensor Amplifiers
D292104.11.fm
Keyence FS-N11CP & FSN12CP Sensor Amplifiers
The
Keyence FS-N11CP
and
FS-N12CP
sensor amplifiers
(shown in Figure A.1 below) are used on the TM-403 for the
Low Cover Tape Sensor
and the
Tape Jam Sensor
. Both
amplifiers are mounted on the
Cover Tape Arm
. The
Low
Cover Tape
amplifier (FS-N11CP) is located on the left. The
Tape Jam
amplifier (FS-N12CP) is located on the right.
The two amplifiers are designed to be attached electrically
and share power. Otherwise, the two units function indepen-
dently of one another.
Selecting the Output Mode
The FS-N11CP/FS-N12CP sensor-amplifiers can be set to two
Output
Modes
:
light-ON
or
dark-
ON
. This determines under what conditions the sensor is triggered and the
Operation Indicator
is
lit.
In
light-ON
mode, the sensor will be triggered when the current value (CV) of detected light from
the emitter is higher than the preset value (PV). In
dark-ON
mode, the sensor is triggered when
the CV of detected light is lower than the PV. Essentially, in
light-ON
Output Mode
the sensor
detects when an obstruction occurs (causing reflected light to increase) and in
dark-ON
Output
Mode
the sensor detects when an obstruction is removed (causing reflected light to decrease).
1.
Press the
Output Selector
button. The
CV Indicator
will display the current mode.
2.
Press the
Manual
button within 5 seconds of having pressed the
Output Selector
button.
The
Output Mode
will be toggled.
3.
The
CV Indicator
will return to its normal display after 5 seconds have elapsed.
Figure A.1
Fiber Lock Lever
Set Button
Preset Value (PV) Indicator
Manual Button
Output Selector
Operation Indicator
Current Value (CV) indicator
Mode Button
Button
Содержание TM-401
Страница 4: ......
Страница 74: ...3 32 TM 401 User s Guide Run Tab D292104 6 fm ...
Страница 146: ...5 44 TM 403 User s Guide Configure Inspection D292104 16 fm ...
Страница 158: ...6 12 TM 401 User s Guide Preparing to Run a Pre programmed Job D292104 8a fm ...
Страница 188: ...7 30 TM 401 User s Guide Adjusting PSA Seal Quality D292104 9a fm ...
Страница 199: ...Appendix A Sensors Contents Keyence FS N11CVP FS N12CP Sensor Amplifiers A 2 SMC ZSE30 Vacuum Sensor A 4 ...
Страница 204: ...Appendix A Sensors A 6 SMC ZSE30 Vacuum Sensor D292104 11 fm ...
Страница 208: ......
Страница 284: ......
Страница 286: ...Service and Parts Contacts 61053915 fm Page 2 ...
Страница 288: ...TM 401 Document List D292104 15b fm Page 2 ...
Страница 290: ......
Страница 291: ......
Страница 292: ...751 Summit Avenue Mankato MN 56001 507 387 2039 FAX 507 387 2257 www vtekusa com Email info vtekusa com ...