Hallett
30 1” Instruction Manual
Released on 1-Sep-16
– X800058R
Page 30
UV Pure Technologies Inc. © 2016
10
Bearing & Base for Wiper Shaft
1
E300142
11
Bearing O ring Seal
1
350011
12
Insert Adapter for Flow Regulator
1
C300075
13
Internal Flow Regulator
1
550201
14
Bracket
– Top, Plain End
1
C300012
15
1/4
” Lock Washer
8
650001
16
Bracket Fastener, 1/4-
20 x 5/8” long
8
650000
17
Top End Cap c/w Shaft guide
1
C300055
18
Shaft Retaining Ring (included in Seal Kit)
1
N/A
19
Seal Washer for SS Hose
– sold in pairs
2
C500009
20
Rubber Washer
– Motor Shaft (Included in Motor Kit)
1
N/A
21
Foam Pad for Motor (Included in Motor Kit)
1
N/A
22
Bottom Bracket Assy c/w Lamp Wire Harness
1
C300068
23
Bottom End Cap Assy
– Motor End c/w Seals
1
C300078
24
Quartz O ring seal (included in Quartz Kit or Seal Kit)
2
N/A
25
Wiper O ring Seal (included in Seal Kit)
1
N/A
26
Washer, Teflon 5/8” ID x 1” OD (included in Seal Kit)
1
N/A
26A
Plastic Washer (included in Wiper Assembly Kit)
1
N/A
27
U Cup Seal for Wiper (included in Seal Kit)
1
N/A
28
Solenoid Shut-off Valve (Normally Closed)
1
550055
29
Display Pad (Membrane switch)
1
E100016
30
Purge Valve Assembly
1
X500000
31
Cold Air Kit
1
X500001
32
Replacement Fuse Pack for 120V units (6 in pack)
1
E400020
33
Replacement Fuse Pack for 240V units (6 in pack)
1
E400021
34
Transient Voltage Surge Suppressor for 115V systems
1
150207
35
Circuit board
– Drinking Water
1
E100065
36
Hallett Diagnostic Tool
1
X100012
37
External 27.4gpm Flow restrictor
– NSF approved
1
CE33
*Older generation Hallett 30s used semi-circular reflector panels
– to reorder
these panels, use p/n E300084T; UV sensors for these units are p/n C100006.
Cleaning/Removing the Quartz Sleeve
Note that numbers in parentheses refer to Figure 4B.
Step 1:
Use a bottle cleaning brush with a long handle to scrub the inside of the
quartz sleeve. Scrub and flush with clean water repeatedly to clean the quartz.
Use a squeeze bottle to apply water or solution to the quartz sleeve to keep the
area tidy.
Note: Keep the rest of the unit free from moisture.
Examine the
quartz by looking through the unit.
Step 2:
If the quartz is still dirty, use a scale remover such as CLR or Lime
Away and apply it to the inside of the quartz sleeve. Citric acid, available at a
drug store, can also be used.
Always flush with clean water afterwards.
Step 3:
Once the quartz is clean, reassemble the unit (see below). Replace any
seals that appear to have been damaged.
Step 4:
If the quartz is still not clean, it requires replacement. This is done by
removing the bottom quartz seal assembly.
Step 5:
Disconnect the wiper motor (5) from the bottom bracket (22) by undoing
the three nuts. See Figure 4C. Pull off the motor plate and foam pad (21) from