When complete, replace the front cover by first reconnecting the 6-pin ribbon
cable to the port marked ‘DISPLAY’ (ensure the black connector is aligned
properly and
do not miss any pins
). Place the front cover in its rest position.
Replace the top cover and screw it down
Cold Air Kit
If cold room conditions cannot be avoided, the Cold Air Kit should be installed.
The kit also helps when water temperatures are very low. The kit consists of
two cover plates, two lamp insulators and two pieces of foil insulation. The cover
plates are to be placed on the top aluminum plate to cover the convection holes.
The foil insulation is placed between the lamp base and bottom endcap. The
lamp insulators are to be wrapped around the bottom of the lamps just below
the bottom aluminum plate. See Figure 1G.
If during the summer months the room temperature exceeds 20°C (68°F), the
Cold Air Kit may be removed and then reinstalled for winter months only.
COVER PLATE
TOP VIEW OF UNIT
LAMP
INSULATOR
BOTTOM VIEW OF UNIT
FOIL INSULATION - INSTALL
BETWEEN LAMP & BTM
ENDCAP. LIFT LAMP TO
INSTALL.
Figure 1G