Reliable Automatic Sprinkler Co., Inc.,

 103 Fairview Park Drive, Elmsford, New York 10523

Models F1 Series
Standard Response
Sprinklers

Bulletin 013 November 2019

Bulletin 013 November 2019

Model F156 Sprinkler Types

Standard Upright
Standard Pendent
Conventional
Vertical Sidewall
Horizontal Sidewall

Model F156 Recessed Sprinkler Types

Pendent/F1/F2/FP
Horizontal Sidewall

Model F142, F1XLH & F128 Sprinkler Types

Standard Upright
Standard Pendent

Model F142, F1XLH & F128 Recessed Sprinkler 
Types

Pendent/F1/F2/FP

Approval Organizations

1.  Underwriters Laboratories Inc. and certified for 

Canada (cULus)

2.  Factory Mutual Approvals (FM)
3.  Loss Prevention Council (LPCB, UK)
4.  VdS Schadenverhütung GmbH
5.  EC Certificate: 0786-CPD-40237 (RA1314)

   

      0786-CPD-40253 (RA1325)

   

      0786-CPD-40254 (RA1375) 

Recessed

Pendent/F1/F2

Horizontal Sidewall

Pendent

Conventional

Upright

Vertical Sidewall

Recessed

Horizontal Sidewall

Recessed

Pendent/FP

XLH Upright

XLH Pendent

XLH Recessed

Pendent F1/F2

XLH Recessed

Pendent FP

UL Listing Category

Sprinklers, Automatic & Open (VNIV)

Product Description

The F156, F142, F1XLH & F128 Series Glass Bulb 

Sprinkler combines the durability of a standard sprinkler 
with the attractive low profile of a decorative sprinkler. 
Whether installed on exposed piping or in an office ceil-
ing, it is functional and attractive. 

Beautifully versatile is the description for the Reliable 

Models F156, F142, F1XLH & F128 Series Recessed 
glass bulb sprinkler. Recessing the F156, F142, F1XLH & 
F128 Series enhances its already low profile decorative 
appearance, and facilitates a rapid and perfect installa-
tion.

The recessed escutcheon of the Models F156, F142, 

F1XLH & F128 are highly adjustable. The two piece con-
struction makes field installation a very easy and rapid 
task. This also allows ceiling panels to later be removed 
without shutting down the fire protection system, thus fa-
cilitating maintenance of above ceiling services.

The F156, F142, F1XLH & F128 Series Automatic Sprin-

kler utilizes a 5.0 mm frangible glass bulb. The glass bulb 
consists of an accurately controlled amount of special 
fluid hermetically sealed inside a precisely manufactured 
glass capsule. This glass bulb is specially constructed to 
provide fast thermal response.

At normal temperatures, the glass bulb contains the 

fluid in both the liquid phase and in the vapor phase. The 
vapor phase can be seen as a small bubble. As heat is 
applied, the liquid expands forcing the bubble smaller 
and smaller as the liquid pressure increases. Continued 
heating forces the liquid to push out against the bulb, 
causing the glass to shatter, opening the waterway and 
allowing the deflector to distribute the discharging water.

The F156, F142, F1XLH & F128 Series Sprinkler tem-

perature rating is identified by the color of the glass bulb 
capsule as well as frame color where applicable.

Содержание F1 Series

Страница 1: ...active Beautifully versatile is the description for the Reliable Models F156 F142 F1XLH F128 Series Recessed glass bulb sprinkler Recessing the F156 F142 F1XLH F128 Series enhances its already low profile decorative appearance and facilitates a rapid and perfect installa tion The recessed escutcheon of the Models F156 F142 F1XLH F128 are highly adjustable The two piece con struction makes field in...

Страница 2: ... F128 2 8 40 Metric Material Data Frame Deflector Load Screw Pintle Cup Washer Bulb DZR Brass QM Brass CDA Alloy 260 CDA Alloy 220 or CDA Alloy 510 CDA Alloy 360 or CDA Alloy 544 CDA Alloy 360 or CDA Alloy 544 CDA Alloy 651 or CDA Alloy 693 Nickel Alloy 440 or Alloy 360 coated with PTFE Adhesive Tape Glass Note Model F156 upright pendent and recessed pendent sprinklers SIN RA1325 and RA1314 are cU...

Страница 3: ...A1375 5 1 Refer to Bulletin 024 for Special Response Sprinklers F1S5 56 2 cULus Listed corrosion resistant Polyester coated sprinkler 3 Polyester coated FM Approved sprinkler 4 5 Polyester coated LPCB VdS approved sprinkler RA1325 RA1314 RA1375 6 Electroless Nickel PTFE Plated UL listed Corrosion Resistant Pendent Conventional Upright Model F156 F142 F1XLH F128 F1 or F2 Model F156 F142 F1XLH F128 ...

Страница 4: ... lead wax and wax over lead 4 Electroless Nickel PTFE Plated cULus listed Corrosion Resistant Model F156 Horizontal Sidewall Sprinkler Deflector HSW Installation Wrench Model W2 Sprinkler Wrench Installation Data Horizontal Sidewall Nominal Orifice Thread Size Nominal K Factor Sprinkler Height Approval Organizations Sprinkler Identification Numbers SIN US Metric Light Hazard Ordinary Hazard 15mm N...

Страница 5: ...t clean sprinklers with soap and water ammonia or any other cleaning fluid Replace any sprinkler which has been painted other than factory applied or damaged in any way A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin klers Prior to installation sprinklers should be maintained in the original cartons and packaging until used to minimize the p...

Страница 6: ...rtment connection Reliable offers a wide selection of sprinkler components Following are some of the many precision made Reliable products that guard life and property from fire around the clock Reliable For Complete Protection Reliable Automatic Sprinkler Co Inc 800 431 1588 Sales Offices 800 848 6051 Sales Fax 914 829 2042 Corporate Offices www reliablesprinkler com Internet Address Manufactured...

Отзывы: