Command WIN:COL:STOP
value
Parameters
value
Return Values
none
Range
3 to 639
Type unsigned
integer
Example
WIN:COL:STOP 429 -- stop read at 429 (must accommodate
location of start)
5.20.4.
Get Window Column Stop Number
Description
Returns the stop column number for the ROI.
Setting Type
Operational
Command WIN:COL:STOP?
Parameters none
Return Values
value
Range
3 to 639
Type unsigned
integer
Example
WIN:COL:STOP?
-- query command
429
--
return
value
5.20.5.
Set Window Row Start Number
Description
Sets the start row number for the ROI. The value must be EVEN
and compatible with the current row stop number for the command
to complete without error.
Setting Type
Operational
Command WIN:ROW:START
value
Parameters
value
Return Values
none
Range
0 to 504
Type unsigned
integer
Example
WIN:ROW:START 64 -- start read at row 64
5.20.6.
Get Window Row Start Number
Description
Returns the start row number for the ROI.