![UTS AEROSPACE SYSTEMS SU640CSX Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/uts-aerospace-systems/su640csx/su640csx_operation-manual_1065633034.webp)
SU640CSX
4110-0462, Rev. B
Page 34 of 97
© 2016 UTC Aerospace Systems
Date Printed: 1-Dec-2016
This document does not contain any export controlled technical data.
operational configuration slot number will return an error.
WARNING: If the startup operational configuration slot is deleted,
the camera startup operation is no longer specified. Use the
OPR:START followed by the CONFIG:SAVE commands to
reselect an existing operational configuration slot if the startup
operational configuration slot is deleted.
Setting Type
N/A
Command OPR:DEL:ALL
Parameters none
Return Values
none
Range
Type
Example OPR:DEL:ALL
5.6.Serial Communication Interface Commands
Baud rate configuration in the volatile memory space is managed with two discrete variables. The first
variable, current baud rate, represents the baud rate at which the camera is currently communicating. The
second variable, future baud rate, holds the baud rate value that will be stored to non-volatile memory
when a global configuration save (CONFIG:SAVE) is executed. Changing the current baud rate will
require the host to change baud rates for communication to continue. Changing the future baud rate and
saving it to non-volatile memory allows for the new baud rate to be effective upon reboot of the camera.
The factory default is 57600 baud. Other serial communication parameters are located in Table 6.
5.6.1.
Set Current Baud Rate
Description
This command updates the current baud rate variable. The baud rate
that the camera communicates at will change immediately.
WARNING: Changing the current baud rate will require the
host to change baud rates for communication to continue.
Setting Type
Global
Command BAUD:CURRENT
baud_rate
Parameters
baud_rate
Return Values
none
Range 57600
115200
230400
460800
Type unsigned
integer
Example BAUD:CURRENT
57600