5.5.4.
Get Current Operational Configuration Number
Description
Returns the current operational slot number that is loaded.
Setting Type
N/A
Command OPR?
Parameters none
Return Values
opr_number
Range
0 to N, maximum value N is OPR:MAX (see command below).
Type unsigned
integer
Example
OPR?
-- query command
5
-- return value
5.5.5.
Get Total Number of Operational Configurations
Description
Returns the number of operational settings currently present in the
User Configuration memory.
Setting Type
N/A
Command OPR:MAX?
Parameters none
Return Values
number
Range
1 to N
Type unsigned
integer
Example
OPR:MAX?
-- query command
8
-- return value
5.5.6.
Set Startup Operational Configuration
Description
Sets the operational slot number that will be loaded on reboot of the
camera. Note: Because this is a global setting, a CONFIG:SAVE
command must subsequently be issued to cause any changes in this
value to be saved to the User Configuration memory. Because the
number of OPRs can change by user action, it is possible to set this
parameter to an invalid OPR.
Setting Type
Global
Command OPR:START
opr_number
Parameters
opr_number
Return Values
none
Range
0 to N, maximum value limited by the number of operational
settings that currently exist.
Type unsigned