![UTS AEROSPACE SYSTEMS SU640CSX Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/uts-aerospace-systems/su640csx/su640csx_operation-manual_1065633064.webp)
SU640CSX
4110-0462, Rev. B
Page 64 of 97
© 2016 UTC Aerospace Systems
Date Printed: 1-Dec-2016
This document does not contain any export controlled technical data.
1000 -- return value
5.13.
Gain Commands
5.13.1.
Set Digital Gain
Description
Sets the digital gain value applied when AGC is off
(AGC:ENABLE OFF). Digital gain can be used to ensure that the
image data fills the digital output range when offset and gain
corrections are applied. In addition, digital gain can be used to
stretch low signal images across a greater portion of the output
range. Digital gain does not inherently improve signal to noise ratio,
except by causing uniform saturation.
This command accepts multiple formats:
Integer input: 1 - 511 (no decimal)
Floating Point: 0.03125 to 16.0 (decimal used) in 1/32 steps
32 = 1.0
Setting Type
Global
Command GAIN:DIGITAL
value
Parameters
value
Return Values
none
Range
1 to 511; 0.03125 to 16.0
Type
decimal OR integer
Example one
of
GAIN:DIGITAL 64
GAIN:DIGITAL 2.0
5.13.2.
Get Digital Gain
Description
Returns the digital gain value in the format it was set.
Setting Type
Global
Command
GAIN:DIGITAL?
Parameters none
Return Values
value
Range
1 to 511; 0.03125 to 16.0