2GN/2GP/2GR
1-5-29
(2) Detaching and refitting the heat roller separation claws
Follow the procedure below to replace the heat roller separation claws.
Procedure
1. Remove the fuser unit. (see page 1-5-28)
2. Remove the two screws and remove the
upper fuser cover while holding the four
claws.
Figure 1-5-59
3. Remove the heat roller separation claws
from the upper fuser cover.
4. Replace the heat roller separation claws and
install the claws to upper fuser cover.
5. Refit the upper fuser cover.
6. Refit the fuser unit.