-22
-
CLOSE TIMER
10
PUSH
BUTTON
LED
GND
OFF
ON
MODE
SINGLE
DUAL
15 AMP
15 AMP
OPEN/CLOSE
PUSHBUTTON
0
10
+12V
CLOSE
LIMIT
OPEN
LIMIT
OPEN
LIMIT
CLOSE
LIMIT
MASTER
SLAVE
ENTRAPMENT
SIREN
OUTPUT
SAFETY
STOP REVERSE
FREE
EXIT
OPEN
INPUT
GN
D
GND
GND
GND
RECEIVER
INPUT
+12V
OUTPUT
0
USAUTOMATIC STAR CONTROL
BOARD
LED
Periodic Service
All gate operators require periodic checking and adjustments by a qualified technician of the
control mechanism for force (load), speed and sensitivity. All external accessories and secondary
safety devices must be checked. Secondary safety devices need to be checked at least once a
month for proper operation.
Periodic checking is also advised for the following:
1.
Battery cells water level. (use distilled water if needed)
2.
Hinges and pivot points need to be greased.
3.
Bolts for correct tightness.
4.
Inspect weld points for cracks or other defects.
5.
Inspect wiring for cuts, knicks or other defects.
6.
Inspect hinge post, ensure that it is not twisting or moving.
Troubleshooting Guide
Introduction
The USAutomatic control board is equipped with two unique features to assist in troubleshooting a gate
system.
1.
The first and most helpful is the series of LED indicating lights. These lights will help to identify
problems with the actuator limit switches and the receiver input. To use the indicators, press and hold
the Push Button Led button on the control board. (The lights are not active at all times to save battery
life). Any circuits or limit switches that are activated will be obvious by the illumination of the adjacent
LED indicating light.
2.
The second feature to assist in troubleshooting is the on board Open/Close Pushbutton.
LED INDICATING LIGHTS
SENSITIVITY
CLOSE
ADJUSTMENT
TIMER
RESET
CLOSE
INPUT
Open/Close Pushbutton
Содержание STAR I