![USAutomatic SENTRY 300 D Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/usautomatic/sentry-300-d/sentry-300-d_installation-and-owners-manual_1064001044.webp)
43
CHARGE CONTROLLER
L.E.D. DESCRIPTIONS
EXTERNAL POWER ADAPTOR
- Illuminates continuously while power from A.C. Power Supply
Adaptor is sensed.
SOLAR PANEL -
Illuminates continuously while power from Solar Panel is sensed.
DETECTION
- If illuminated for longer than 3 seconds check connection on battery.
CHARGING
- Continuous or flashing indicates charging.
CHARGED
- On continuously when input power is present and battery fully charged. Flashes when
battery capacity is low.
SYSTEM ERROR
- If flashing, the charger has entered Failure Mode. Disconnecting power will
reset charger, but if source of failure is not corrected, Failure Mode will occur again.- refer
to the following Table to Decode the Error Type:
L.E.D.s
(First 4 L.E.D.s from Left)
1st
2nd
3rd
4th
Wrong Battery Voltage
Off
Off
Off
Flash
Reverse Battery Connection
Off
Off
Flash
Off
Thermal Runaway Condition
Off
Flash
Off
Off
Charge Time Monitor - 1
Off
Flash
Flash
Off
Charge Time Monitor - 2
Off
Flash
Flash
Flash
Excessive Battery Drain
Flash
Off
Off
Off
Failed Pre-Qualification Test -1
Flash
Off
Off
Flash
Failed Pre-Qualification Test -2
Flash
Off
Flash
Off
C