![USAutomatic SENTRY 300 D Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/usautomatic/sentry-300-d/sentry-300-d_installation-and-owners-manual_1064001016.webp)
15
Sentry Plug N Go Harness
The Plug N Go Harness comes preinstalled and should be plugged
into the bottom of the charge controller. Plug is color coded. Red
connects to positive battery post and Black connects to negative
battery post. Once connected, place harness into wire compartment to
prepare for battery installation.
Install Battery
BATTERY REQUIRED FOR OPERATION
(Battery not included)
Recommended battery type - 12-volt, Group U-1; sealed
(maintenance free); 30 amp hour minimum. This battery is
sometimes described as a non-spillable lawn tractor battery. Battery
physical size must not exceed 9” wide, 7” tall and 5 3/4” deep.
The Plug N Go harness has two 1/4” ring terminals to connect to
bolt type battery post.
CAUTION
- Do not install wet cell battery into control box; this type
of battery usually has removable caps used for service and will vent
corrosive fumes into control box.
1. Install the battery into the battery compartment.
2. Connect O ring terminals from harness to the battery.
NOTE:
Red wire to positive post of battery
Black wire to negative post of battery
3. Tighten the bolts securely (bolts should be supplied with the battery).
10
11
1/4” Ring terminal for battery
Red connects to positive battery post
Black connects to negative battery post
Charge controller connector
15 amp fuse
Gate 1 and Gate 2 linear
actuator power plugs