34
Making Final Adjustments
Once the gate has traveled to the stop position in both directions, adjust the Gate 1 “Extend Limit
More or Less” adjustment dials located on the control board.
Turn the adjustment slightly clockwise to close gate more, cycle gate and repeat until close position is
correct. If gate is adjusted past the desired closed position turn the adjustment
counter clockwise slightly.
Then cycle the gate to verify close position is correct.
Repeat for second gate using Gate 2 “Extend Limit More or Less” Adjustments.
Sensitivity Adjustments and Entrapment Alarm
The Ranger control board has 2 sensitivity adjustment dials located in the
upper left corner of the control board. These adjustments control the amount
of current the control board will allow the motor to draw from the battery to
operate your gate. Minimum force is the least amount of current
allowed. This circuit is inactive for the first second of gate operation.
A typical adjustment setting is between 4 to 7 on the adjustment dial. If a
setting above 8 is required for proper operation without just cause, you should
check the gate, gate hinges or linear actuator for possible problems.
Both sensitivity settings should be individually adjusted on dual gate systems.
On single gate systems, adjust the setting for the actuator plug being
utilized (Gate 1 or Gate 2) and then match the setting on the other sensitivity
adjustment.
22
23
Extend
Retract
System Reset
Open / Close
Command