6. Trouble Shooting
Symptom
Possible Reasons
Possible Solution
Tool does not run.
・
Battery is not attached.
・
Battery power indicator does not turn on.
・
The tool is under heat protection.
・
Battery Power Indicator turns red.
・
Wire breakage inside the tool
・
ZigBee Communication LED does not turn on.
・
ZigBee communication is not alive.
●Insert battery to the tool and touch grip switch.
●Do not use the tool until the motor cools down.
(Leave the ventilator work until it stops, which will
expedite the motor cool down.)
●Change batteries.
(Recharge the removed battery.)
●Repair or replace
●Check conditions (power & communication) of
upper equipment such as Uzig coordinator,
UEC-4800(SD), UCC-100Z. Remove battery once
and attach battery again and press the grip switch.
●See ZigBee communication error.
Unexpected direction of rotation
・
Unintentional change of Fwd/Rev lever position
●Set Fwd/Rev lever to the correct position for your job.
Tool does not work properly.
・
Breakage of part(s) or missing part(s)
・
Low setting parameters for Current and/or Speed
・
Excessive load
●Repair or replace.
●Review parameters for Current and Speed
●Load reduction
Ventilator does not work.
・
Breakage of ventilator
・
Breakage of wire for ventilation inside the tool
●Repair or replace
Buzzer does not sound.
・
Breakage
●Repair or replace
Out of torque control
・
Incorrect setting parameter
・
Wire breakage inside the tool
・
Sensor breakage
●Double check setting parameter such as CAL and
change parameters.
●Repair or replace
Does not measure;
- angle
- fastening time
- pulse count
・
Incorrect setting parameter
・
Wire breakage inside the tool
・
Sensor breakage
●Review setting parameter for your job.
●Repair or replace
Too long fastening time
・
Tool overheats.
・
Oil leakage
●Review the current process / tool model.
●Repair or replace
Sensor Error
(ZERO Error, CAL Error etc.)
・
Sensor breakage / Wire breakage
●Repair or replace
●See instruction manual of UEC-4800 / UCC-100Z.
ZigBee Communication Error
・
Long distance between the tool and the coordinator.
・
Condition (radio frequency) at
workplace has changed.
・
Cable disconnection
・
Wire breakage / Breakage of related part(s)
●Review install location.
●Recheck updated radio frequency
Condition at workplace and if
necessary, make pairing again.
●Check connection of the system.
●Repair or replace