14. PROGRAMMING AND USE OF THE SIMPLIFIED GUI
Simpli
fi
ed GUI is used to select to use a very simple user interface (GUI) allowing the user to select one or
more columns (or blocks) in the system and enter the number of the apartment to be called.
To enter the programming procedure, see paragraph 8.1.
To change the language of the calling module, see paragraph 8.2
14.1 CONFIGURATION OF PRIMARY CALLING MODULE
Select CONFIGURATION on the main menu. The menu shown to the side
appears where the user can press the
, to select
YES
.
Then select the type of PRIMARY module with the
buttons and press
OK
to con
fi
rm.
The following screen appears and it is used to de
fi
ne which columns (or blocks)
may be called from the calling module. Ranges which include only some of
the blocks present in the system may be de
fi
ned (e.g. FROM:3 TO: 12). After
having inserted a range of blocks, a default name will be assigned to each
block, e.g. BLOCK X, where X means A for the
fi
rst block (the one with column
0 addresses), B the second block (column 1 addresses) and so on to block 25.
Blocks from 26 to 31 will be identi
fi
ed by letters ZA ÷ ZF. The default names
can be customized in the second level BLOCKS menu described below. The
following screenshot shows an example of con
fi
guration for calling six blocks.
If the user wants to call a single block from the PRIMARY calling module,
the BLOCKS INTERVAL must be con
fi
gured as follows:
FROM: X
TO: X
Where X is the number of the block to be called.
The default value of the interval is
FROM: 0
TO: 0