![urmet domus ELEKTA STEEL Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/urmet-domus/elekta-steel/elekta-steel_installation-programming-and-use-instruction-manual_1062334076.webp)
76
DS1083-046A
Press
OK
to con
fi
rm the reset operation or
X
to cancel and go back to the
main menu.
9. BLUETOOTH
PROGRAMMING
The calling module can be programmed directly or alternatively using a personal computer (PC) or a portable
device (tablet or mobile phone) with Bluetooth interface and dedicated software.
The software may be downloaded from Download\Software section of the www.urmet.com website.
Instructions on how to program via Bluetooth and the respective procedures are illustrated in the instruction
booklet provided with the software.
The keypad of the calling module will be deactivated when the Bluetooth connection is established except
for the
X
button which can be used to interrupted the calling module remote programming procedure.
IMPORTANT:
Asynchronous interruption by pressing the
X
button may cause unpredictable results on
the data stored in the calling module (similar to interrupting a common data download operation). Use this
function only in case of actual use.
10. TECHNICAL SPECIFICATIONS
Direct current power voltage (LINE) ............................................................................................. 36 – 48 V
Stand-by draw ............................................................................................................................. 130 mA max
Max. draw (video conversation) ..........................................................................................................200 mA
Lock output (SE+ SE-) .......................................................................................... Hold current: 270 mA max.
Peak load: 15 VA
Relay contacts C, NC, NO ......................................................................Max. switching voltage: 30 Vdc/Vac
Max. switching current: 3.5 A
Max. switching load: 40 VA – 25 W
Relay contact SE2 (vehicle gate) ............................................................Max. switching voltage: 30 Vdc/Vac
Max. switching current: 200 mA
ILA ...................................................... Hearing aid compliant audio output, European law SOCU0611477A
Max. distance between door opening button
and calling module ................................................... 25 m / 82 ft, wire cross section area 1.5 mm
2
(AWG15)
Max. distance between door open sensor
and calling module ................................................. 50 m / 164 ft, wire cross section area 1.5 mm
2
(AWG15)
Temperature ..........................................................................................................-10 ÷ +50 °C / 14 ÷ 122 °F
Degree of protection codes: 1083/15 and 1083/25 .................................................................................. IP44
codes: 1083/16 and 1083/27 .................................................................................. IP43
10.A. LEGEND
Symbol
Explanation
DC supply voltage
10.B. DECLARATION OF CONFORMITY TO DIRECTIVE 1999/5/EC
Hereby Urmet S.p.A., declares that these 2Voice Elekta and Elekta Steel calling modules (1083/15 and
1083/16 codes) are in compliance with the essential requirements and other relevant provisions of Directive
1999/5/EC.
The declaration of conformity may be consulted at www.urmet.com or can be requested to the Urmet
Customer Service.
Содержание ELEKTA STEEL
Страница 91: ...91 DS1083 046A...