No:
allow you select one desired channel
•
I/O Status:
allows you select the three options – NO (Normal Open), NC (Normal Close) and OFF. Set to “Normal Open”, I/O
status Alarm will be activated while sensor is ON; set to “Normal Close”, I/O status alarm will be activated while sensor is
OFF; set to “OFF”, I/O status alarm will not be triggered.
•
Alarm Out:
allow you connect external alarm sensor.
•
Alarm Out Time:
you can set how long the external sensor alarm will last when sensor alarm is detected (10sec, 20sec,
40sec, and 60sec);
•
Show icons:
You can set show the icon on the screen when sensor alarm is detected. About icons type please refer to
Section 4.
•
Buzzer time:
you can set how long the buzzer will sound when sensor alarm is detected (OFF, 10sec, 20sec, 40sec, 60sec);
•
Send Email
: Allows you set the alarm images is issued to a specified email.
•
Full screen Alarm:
you can set how long the video is displayed in full screen mode when sensor alarm or external alarm is
detected (OFF,1sec, 2sec, 3sec, 5sec, 7sec, 10sec, 20sec, 30sec);
•
Record Channel:
the record channel will be activated when the object move is detected.
•
Post Recording:
you can set how long alarm record will last when alarm ends (10sec, 30sec, 1min, 2min, 5min).
•
Copy:
allow you copy current channel parameters to any other channel or all channels.
Alarm Type
Function
Motion
Detection
When an object moves into motion detection area, alarm will be triggered. You can adjust
sensitivity level to suit the needs of your actual application environment.
I/O Status
System can convert alarm signal triggered by external sensor into signal identified by system.