urmet domus 1033/470 Скачать руководство пользователя страница 8

14

DS1033-124

15

DS1033-124

In 1033/471 model, if incoming calls are disabled, the GSM module is turned off and it is automatically 

activated again, when it is necessary to perform an alarm call. In this way the current consumption is 

reduced: this is very useful when the alarm control panel that supplies the dialer is powered by the 

backup battery. The GSM module operates in a similar way in 1033/472 model, with the following 

parameters con

fi

 gurations: parameter 503 = 0 or parameter 503

 0 and parameter 508 = 0.

Trunk access code for PABX

: if the telephone dialer is connected to the PSTN line by a PABX, it is 

possible to con

fi

 gure the trunk line access code, that will be automatically dialled before the programmed 

telephone numbers.

Telephone channel priority

: with the telephone dialer 1033/472 model, equipped with both PSTN and 

GSM modules, it is possible to select which of them will be used for the alarm message sending. If the 

priority telephone channel is not available (for example for a line failure or for no GSM 

fi

 eld), when it is 

necessary to send an alarm message, the telephone dialer will automatically use the other channel.

Call delay

: it determines the input activation time before an alarm signalling is generated. The correct 

con

fi

 guration of this parameter allows to avoid false alarm signalling, because, for example, the user has 

forgotten to disarm the alarm system.

Call cycles

: it determines how many times the call cycle is repeated. The call cycle includes the sequential 

call of the telephone numbers associated to the call diversion function and associated to the alarmed 

input.

In the the following table are shown the telephone parameters, the allowed values and the default values.

Parameter Description

Allowed values

Factory 

value

Telephone parameters programming

501

Dial tone check

0 = disabled

1 = enabled

0

502

Answer check

0 = disabled

1 = enabled

0

503

Rings for incoming call

0, 1, 3, 5, 7

5

507

Trunk access code for PABX

4 digits max
Button 

: The trunk access code, 

if already stored, is deleted.

508

Telephone channel priority

0 = PSTN

1 = GSM

0

610

Call delay

0 = 250 ms

1 = 3 s

2 = 20 s

0

620

Call cycles

1, 2, 3, 4, 5

3

After entering the value, press button 

 to con

fi

 rm.

It is possible to check the parameter current con

fi

 guration, or if a value is correct, by entering the respective 

parameter followed by button 

 instead of button 

.

§

2.3.3 TELEPHONE CONNECTION TEST 

GSM field test (1033/471 and 1033/472 models)

It allows to check the GSM 

fi

 eld level. To perform the test, follow the instructions below:

User action 

Dialer answer

Enter 

504#

Press 0 to start the GSM 

fi

 eld test

Enter 

0

Please wait

. Some beeps are emitted; during this time the 

test is performed. At the end, are possible the following 

answers:

Excellent GSM 

fi

 eld 

Good GSM 

fi

 eld 

Low GSM 

fi

 eld 

No GSM 

fi

 eld

GSM call test (1033/471 and 1033/472 models)

It allows to perform a test call with the GSM module. The called number is the call diversion function 

number and only the main message is played. To perform the test, follow the instructions below: 

User action 

Dialer answer

Enter 

505#

Press 0 to start the test call

Enter 

0

The test call is performed

Warning

: before performing the test, check that the call diversion number has been programmed 

(parameter 100).

PSTN call test (1033/470 and 1033/472 models)

It allows to perform a test call with the PSTN module. The called number is the call diversion function 

number and only the main message is played. To perform the test, follow the instructions below:

User action 

Dialer answer

Enter 

506#

Press 0 to start the test call

Enter 

0

The test call is performed

Warning

: before performing the test, check that the call diversion number has been programmed 

(parameter 100).

2.3.4 PROGRAMMING PARAMETERS

 

It is possible to con

fi

 gure the programming procedure, by enabling or disabling the voice driven menu 

and the selected language. If voice messages are disabled in programming mode, the dialer will signal the 

operations to be performed or their result as follows:

Short beep: enter a value

Long beep: error

Beep-beep: the entered value has been stored

Parameter Description

Allowed values

Factory 

value

Programming parameters

640

Language selection for pre-recorded 

messages

0 = Italian

1 = English

0

650

Voice messages in programming mode

0 = disabled

1 = enabled

1

After entering the value press the button 

 to con

fi

 rm.

It is possible to check the parameter current con

fi

 guration, or if a value is correct, by entering the respective 

parameter followed by button 

 instead of button 

.

Содержание 1033/470

Страница 1: ...DS 1033 124 LBT 8355 Mod 1033 TELEPHONE DIALER Ref 1033 470 Ref 1033 471 Ref 1033 472...

Страница 2: ...4 user defined recordable alarm messages 4 telephone numbers associated to every input 12Vdc 10 15Vdc nominal power voltage Programmable number of call cycles 1 5 Programmable call delay GSM field tes...

Страница 3: ...elephone numbers associated to the alarmed input The message text is Urmet Security System Alarm on input X where X may be 1 2 3 or 4 and indicates the input in alarm state The other programmed voice...

Страница 4: ...pause one of the available commands is entered 1 2 3 4 or 9 the alarm call cycle is stopped see paragraph Alarm calls cycle interruption and the selected remote device is activated the dialer sends t...

Страница 5: ...ming procedure 301 Outputenablingfortelephoneconnection failure signalling failure on PSTN line or GSM field loss 0 signalling disabled 1 signalling enabled in case of failure the output relay is acti...

Страница 6: ...S messages sending 0 SMS messages enabled 1 SMS messages disabled 1 Various programming procedures 630 Follow me function 0 function disabled 1 function enabled 0 660 Password configuration for access...

Страница 7: ...associated to the message to be deleted followed by the button Start message recording after the acoustic signal Press again the button Recorded message 2 3 ADVANCED PROGRAMMING Theadvancedprogramming...

Страница 8: ...entering the value press button to confirm It is possible to check the parameter current configuration or if a value is correct by entering the respective parameter followed by button instead of butt...

Страница 9: ...irreversible and all configurations are deleted telephone numbers voice messages etc After a reset a new programming procedure is needed 3 MAINTENACE 3 1 CLEANING To clean the telephone dialer use a d...

Страница 10: ...it along its guides 3 Put the SIM in the holder taking care contacts are visible and put again the holder in its housing when sliding the holder SIM contacts must face the GSM module WARNING correct o...

Страница 11: ...of an alarm For the connection of the microphone used for environmental listening Ref 1061 003 use a twisted pair The line must not be longer than 100m in connection polarity must be respected The tam...

Страница 12: ...5mm2 section cable Max distance from inputs activation contacts IN1 IN2 IN3 IN4 to the PSTN GSM dialer 150m with 0 5mm2 section cable Max distance from PSTN GSM dialer output relay to KLIMAT ZOOM chro...

Страница 13: ...ef 39 011 24 00 000 RIC AUT Fax 39 011 24 00 300 323 Area tecnica servizio clienti 39 011 23 39 810 Fabbricato da Urmet Electronics Limited un azienda del gruppo Urmet Made in PRC Manufactured by Urme...

Отзывы: