urmet domus 1033/470 Скачать руководство пользователя страница 3

4

DS1033-124

5

DS1033-124

1.1.2 COMMAND AND DISPLAYING ELEMENTS

3

2

1

1

 

RJ12 socket for programming telephone

2

 

Programming button

3

 

Signalling LED

The dialer is equipped with a 

fl

 ush mounting button in safe position for the programming and a two-colour 

LED, placed in the front panel, used to signal the device correct operation and state.

The LED can signal:

LED colour

Meaning

Green

Normal operation

Red

Damaged module or malfunction

Yellow

Programming state

A fast blinking LED means that an alarm call is in progress.

A slow blinking LED means that an alarm calls cycle is in progress, but the call is not in progress (interval 

between two consecutive calls).

1.2 OPERATION PRINCIPLES

1.2.1 VOICE ALARM MESSAGE STRUCTURE

The voice alarm message is composed by two parts:

The basic message, containing information as user name and place where the event occurred.

The event message, specifying the occurred event. There are 4 different event messages, one for every 4 

alarm inputs of the dialer. The event messages follows immediately the main message.

All the messages can be customized.

1.2.2 ALARM DETECTION

The telephone dialer detects an alarm when the state of an input changes. Every input is associated to a 

speci

fi

 c voice alarm message and to different telephone numbers to be dialled.

When an input detects an alarm state, the alarm call procedure starts. 

1.2.3 ALARM CALL PROCEDURE

When a dialer input detects an alarm signal, the following operations are performed:

PSTN telephone network for the devices connected after the dialer is disconnected and telephone 

conversations, if present, are interrupted (for dialers with PSTN module only).

The telephone dialer seizes the telephone line.

The 

fi

 rst cycle of voice calls is performed. For every call the alarm message is repeated for 3 times. 

If the SMS messages sending feature has been enabled (parameter 509), after the 

fi

 rst cycle of calls, an 

alarm SMS message is sent to all the telephone numbers associated to the alarmed input. The message 

text is: “Urmet Security System - Alarm on input X”, where X may be 1, 2, 3 or 4 and indicates the input 

in alarm state. 

The other programmed voice call cycles are performed. 

The alarm call of input 1 has an higher priority than the alarm call of input 2, etc., i.e. if several alarm events 

occur, the alarm of input 1 is signalled before all the others, etc. 

1.3 FUNCTIONS

1.3.1 ALARM CALL CYCLE INTERRUPTION

During the call cycle, every programmed number is called from 1 to 5 times, according to the programmed 

parameter.

The telephone alarm message is repeated for 3 times, as shown in the following diagram, where “basic 

message” is the customized message recorded by the user (for example “Paolo Verdi’s apartment, via 

Roma 15, Milano”) and “event message” is the alarm message associated to every input. 

Each time the alarm message is repeated, a short “beep” will be heard, followed by a pause of 5 seconds. 

After the alarm message has been repeated as many times as programmed in the con

fi

 guration, the dialer 

stops the communication and calls the next telephone number stored for this event kind, if present.

Basic message
Event message
Beep
Block waiting

15 s
5 s
0,5 s
5 s

Basic message
Event message
Beep
Block waiting

Basic message
Event message
Beep
Block waiting

It is possible to stop in advance the calls cycle by dialling, during the 5 seconds pause, the code 22 with a 

DTMF telephone. In this case, the message will not be repeated, other telephone numbers programmed for 

that event kind will not be called and SMS will not be sent, if enabled. 

Basic message
Event message
Beep
Block waiting

15 s
5 s
0,5 s
5 s

ENTER 22

CYCLE BLOCK

This function is especially useful when several telephone numbers has been programmed for the same 

event (for example of

fi

 ce telephone, mobile or telephone of parents or other relatives), because are avoided 

not necessary alarm signalling after the 

fi

 rst alarm has been received.

After the call cycles has been stopped, it is possible to send commands to the device with DTMF tones (see 

the following paragraph).

To stop the telephone call press the button 0! 

§

Содержание 1033/470

Страница 1: ...DS 1033 124 LBT 8355 Mod 1033 TELEPHONE DIALER Ref 1033 470 Ref 1033 471 Ref 1033 472...

Страница 2: ...4 user defined recordable alarm messages 4 telephone numbers associated to every input 12Vdc 10 15Vdc nominal power voltage Programmable number of call cycles 1 5 Programmable call delay GSM field tes...

Страница 3: ...elephone numbers associated to the alarmed input The message text is Urmet Security System Alarm on input X where X may be 1 2 3 or 4 and indicates the input in alarm state The other programmed voice...

Страница 4: ...pause one of the available commands is entered 1 2 3 4 or 9 the alarm call cycle is stopped see paragraph Alarm calls cycle interruption and the selected remote device is activated the dialer sends t...

Страница 5: ...ming procedure 301 Outputenablingfortelephoneconnection failure signalling failure on PSTN line or GSM field loss 0 signalling disabled 1 signalling enabled in case of failure the output relay is acti...

Страница 6: ...S messages sending 0 SMS messages enabled 1 SMS messages disabled 1 Various programming procedures 630 Follow me function 0 function disabled 1 function enabled 0 660 Password configuration for access...

Страница 7: ...associated to the message to be deleted followed by the button Start message recording after the acoustic signal Press again the button Recorded message 2 3 ADVANCED PROGRAMMING Theadvancedprogramming...

Страница 8: ...entering the value press button to confirm It is possible to check the parameter current configuration or if a value is correct by entering the respective parameter followed by button instead of butt...

Страница 9: ...irreversible and all configurations are deleted telephone numbers voice messages etc After a reset a new programming procedure is needed 3 MAINTENACE 3 1 CLEANING To clean the telephone dialer use a d...

Страница 10: ...it along its guides 3 Put the SIM in the holder taking care contacts are visible and put again the holder in its housing when sliding the holder SIM contacts must face the GSM module WARNING correct o...

Страница 11: ...of an alarm For the connection of the microphone used for environmental listening Ref 1061 003 use a twisted pair The line must not be longer than 100m in connection polarity must be respected The tam...

Страница 12: ...5mm2 section cable Max distance from inputs activation contacts IN1 IN2 IN3 IN4 to the PSTN GSM dialer 150m with 0 5mm2 section cable Max distance from PSTN GSM dialer output relay to KLIMAT ZOOM chro...

Страница 13: ...ef 39 011 24 00 000 RIC AUT Fax 39 011 24 00 300 323 Area tecnica servizio clienti 39 011 23 39 810 Fabbricato da Urmet Electronics Limited un azienda del gruppo Urmet Made in PRC Manufactured by Urme...

Отзывы: