2.2 BASIC PROGRAMMING

The basic programming concerns the dialer main parameters: telephone numbers, alarm messages 

recording, SMS messages enabling, call diversion function enabling, message language selection and 

access password change. These parameters can also be changed by the 

fi

 nal user, with care.

2.2.1 PARAMETERS AND VALUES

The following table shows the different basic parameters, allowed values and factory values.

Parameter Description

Allowed values

Factory 

value

Telephone numbers programming procedure

100

Telephone number associated to the call 

diversion function

Telephone number to be stored 

(20 digits max, pauses included); 
in order to enter a pause, digit 

 

after one digit at least has been 

entered.

If the telephone number is not 

entered within one minute, the 

dialer emits a long beep and 

waits for a new parameter.

§

no

111

Input 1, telephone number 1

112

Input 1, telephone number 2

113

Input 1, telephone number 3

114

Input 1, telephone number 4

121

Input 2, telephone number 1

122

Input 2, telephone number 2

123

Input 2, telephone number 3

124

Input 2, telephone number 4

131

Input 3, telephone number 1

132

Input 3, telephone number 2

133

Input 3, telephone number 3

134

Input 3, telephone number 4

141

Input 4, telephone number 1

142

Input 4, telephone number 2

143

Input 4, telephone number 3

144

Input 4, telephone number 4

SMS messages programming procedure

509

SMS messages sending

0 = SMS messages enabled

1 = SMS messages disabled

1

Various programming procedures

630

Follow me function

0 = function disabled

1 = function enabled

0

660

Password con

fi

 guration for access to 

programming procedure

Free numeric code, from 4 to 6 

digits. Codes with more digits allow 

a wider security.

Warning

: write in a safe place the 

entered password, that is necessary 

to access to the programming 

procedure.

000000

After entering the value, press 

 to con

fi

 rm.

PROGRAMMING EXAMPLES

Telephone number entering.

To programm the telephone number 011240086 as 2nd telephone number associated to input 3, follow the 

instructions below:

User action 

Dialer answer

Enter 

132#

Enter the telephone number 2 associated to input 3

Enter 

011240086

Parameter stored

Telephone number check

To check the telephone number associated the second telephone number of input 3, follow the 

instructions below:

User action 

Dialer answer

Enter 

132*

The telephone number associated to input 3 is 

011240086

Telephone number deleting

To delete the telephone number associated the second telephone number of input 3, follow the 

instructions below: 

User action 

Dialer answer

Enter 

132#

Enter the telephone number 2 associated to input 3

Enter 

#

Parameter deleted

Access password change

To change the access password and con

fi

 gure as password, for example, the code 123456, follow 

the instructions below:

User action 

Dialer answer

Enter

 660#

Enter the new password

Enter 

123456#

Enter again the password 

(Enter the password twice is 

a security procedure to avoid errors when digiting the 

choosen password)

Enter 

123456#

Parameter saved

Содержание 1033/470

Страница 1: ...DS 1033 124 LBT 8355 Mod 1033 TELEPHONE DIALER Ref 1033 470 Ref 1033 471 Ref 1033 472...

Страница 2: ...4 user defined recordable alarm messages 4 telephone numbers associated to every input 12Vdc 10 15Vdc nominal power voltage Programmable number of call cycles 1 5 Programmable call delay GSM field tes...

Страница 3: ...elephone numbers associated to the alarmed input The message text is Urmet Security System Alarm on input X where X may be 1 2 3 or 4 and indicates the input in alarm state The other programmed voice...

Страница 4: ...pause one of the available commands is entered 1 2 3 4 or 9 the alarm call cycle is stopped see paragraph Alarm calls cycle interruption and the selected remote device is activated the dialer sends t...

Страница 5: ...ming procedure 301 Outputenablingfortelephoneconnection failure signalling failure on PSTN line or GSM field loss 0 signalling disabled 1 signalling enabled in case of failure the output relay is acti...

Страница 6: ...S messages sending 0 SMS messages enabled 1 SMS messages disabled 1 Various programming procedures 630 Follow me function 0 function disabled 1 function enabled 0 660 Password configuration for access...

Страница 7: ...associated to the message to be deleted followed by the button Start message recording after the acoustic signal Press again the button Recorded message 2 3 ADVANCED PROGRAMMING Theadvancedprogramming...

Страница 8: ...entering the value press button to confirm It is possible to check the parameter current configuration or if a value is correct by entering the respective parameter followed by button instead of butt...

Страница 9: ...irreversible and all configurations are deleted telephone numbers voice messages etc After a reset a new programming procedure is needed 3 MAINTENACE 3 1 CLEANING To clean the telephone dialer use a d...

Страница 10: ...it along its guides 3 Put the SIM in the holder taking care contacts are visible and put again the holder in its housing when sliding the holder SIM contacts must face the GSM module WARNING correct o...

Страница 11: ...of an alarm For the connection of the microphone used for environmental listening Ref 1061 003 use a twisted pair The line must not be longer than 100m in connection polarity must be respected The tam...

Страница 12: ...5mm2 section cable Max distance from inputs activation contacts IN1 IN2 IN3 IN4 to the PSTN GSM dialer 150m with 0 5mm2 section cable Max distance from PSTN GSM dialer output relay to KLIMAT ZOOM chro...

Страница 13: ...ef 39 011 24 00 000 RIC AUT Fax 39 011 24 00 300 323 Area tecnica servizio clienti 39 011 23 39 810 Fabbricato da Urmet Electronics Limited un azienda del gruppo Urmet Made in PRC Manufactured by Urme...

Отзывы: