5. TECHNICAL CHARACTERISTICS

Power supply nominal voltage: 

12Vdc 

Max current during call:  

100mA (1033/470)

   

500mA (1033/471 and 1033/472)

Current consumption in stand-by: 

60mA (1033/470)

   

70mA (1033/471 and 1033/472)

Telephone number dialling: 

DTMF

Outputs for electric loads: 

1, relay, NC/NO, programmable, connection with screw terminal pins

Switching max current:  

1A resistive

Switching max voltage:  

24Vdc

GSM antenna connection (1033/471 and 1033/472): 

Female SMA connector

Connection for message programming and recording: 

RJ12 connector

Working temperature range: 

0 ÷ +50°C, relative humidity 95% @ 45°C

Protection degree: 

IP40

Max dimensions (h x w x d): 

150 x 136 x 46mm

Weight: 

350g

6. CONNECTION DIAGRAMS

SSF112-0280

F.069

:  Max. distance from the control panel 

or power supply equipped with backup 

battery to:

 PSTN 

dialer:

 

150m with 0,5mm

2

 section cable.

 GSM 

dialer:

 

35m with 0,5mm

2

 section cable.

 

Max. distance from inputs activation 

contacts (IN1, IN2, IN3, IN4) to the PSTN/

GSM dialer: 150m with 0,5mm2 section 

cable.

 

Max. distance from PSTN/GSM 

dialer output relay to KLIMAT ZOOM 

chronothermostat: 40m, with 0,5mm2 

section cable.

 

Max. distance from the PSTN/GSM dialer 

to the informative report and environmental 

listening: 100m with 0,5mm

2

 section 

twisted pair. 

VX.008

  Connect the devices to a 

fi

 lter and power 

line protection device.

1

2

IN

OUT

2

1

Ref.1332/85

2

1

Ref.1332/86

IN

OUT

2

1

N

L

N

L

Protection

Filter

Mains~

Line~

Utility

(Neutral)

Earth

(Step)

Sch.1056/024A-034A

CONTROL PANEL

Sch.1061/013

INFORMATIVE REPORT AND

ENVIRONMENTAL LISTENING

TO THE FIRST TELEPHONE

LINE~

Sch.1430/3
KLIMAT ZOOM
CHRONOTHERMOSTAT

BOILER

NC CONTACT
EXAMPLE
BOILER
BLOCK

NO CONTACT
EXAMPLE
PUMP
FAILURE

(VX.008)

THERMOSTAT

~0

~230

ae

au

bu

be

SAB

-RV

U3

-RV

+RV

U2

NO

NC

C

U1

urme

t

(COM)5

1

2

3

4

(NC)6

(NO)7

NC

C

+V

SABO

SABI

NO

GND

IN1

LINE

PHONE

+MIC

-MIC

IN2

IN3

IN4

-MIC

+SPK

-SPK

+MIC

Sch.1332/81

TELEPHONE LINE SURGE

PROTECTION DEVICE

FROM THE
TELEPHONE LINE

Sch.1033/472
TELEPHONE DIALER

Содержание 1033/470

Страница 1: ...DS 1033 124 LBT 8355 Mod 1033 TELEPHONE DIALER Ref 1033 470 Ref 1033 471 Ref 1033 472...

Страница 2: ...4 user defined recordable alarm messages 4 telephone numbers associated to every input 12Vdc 10 15Vdc nominal power voltage Programmable number of call cycles 1 5 Programmable call delay GSM field tes...

Страница 3: ...elephone numbers associated to the alarmed input The message text is Urmet Security System Alarm on input X where X may be 1 2 3 or 4 and indicates the input in alarm state The other programmed voice...

Страница 4: ...pause one of the available commands is entered 1 2 3 4 or 9 the alarm call cycle is stopped see paragraph Alarm calls cycle interruption and the selected remote device is activated the dialer sends t...

Страница 5: ...ming procedure 301 Outputenablingfortelephoneconnection failure signalling failure on PSTN line or GSM field loss 0 signalling disabled 1 signalling enabled in case of failure the output relay is acti...

Страница 6: ...S messages sending 0 SMS messages enabled 1 SMS messages disabled 1 Various programming procedures 630 Follow me function 0 function disabled 1 function enabled 0 660 Password configuration for access...

Страница 7: ...associated to the message to be deleted followed by the button Start message recording after the acoustic signal Press again the button Recorded message 2 3 ADVANCED PROGRAMMING Theadvancedprogramming...

Страница 8: ...entering the value press button to confirm It is possible to check the parameter current configuration or if a value is correct by entering the respective parameter followed by button instead of butt...

Страница 9: ...irreversible and all configurations are deleted telephone numbers voice messages etc After a reset a new programming procedure is needed 3 MAINTENACE 3 1 CLEANING To clean the telephone dialer use a d...

Страница 10: ...it along its guides 3 Put the SIM in the holder taking care contacts are visible and put again the holder in its housing when sliding the holder SIM contacts must face the GSM module WARNING correct o...

Страница 11: ...of an alarm For the connection of the microphone used for environmental listening Ref 1061 003 use a twisted pair The line must not be longer than 100m in connection polarity must be respected The tam...

Страница 12: ...5mm2 section cable Max distance from inputs activation contacts IN1 IN2 IN3 IN4 to the PSTN GSM dialer 150m with 0 5mm2 section cable Max distance from PSTN GSM dialer output relay to KLIMAT ZOOM chro...

Страница 13: ...ef 39 011 24 00 000 RIC AUT Fax 39 011 24 00 300 323 Area tecnica servizio clienti 39 011 23 39 810 Fabbricato da Urmet Electronics Limited un azienda del gruppo Urmet Made in PRC Manufactured by Urme...

Отзывы: