urmet domus 1033/470 Скачать руководство пользователя страница 10

18

DS1033-124

19

DS1033-124

4. INSTALLATION

Warning

: the telephone dialer installation must be executed by a skilled technical staff, according to current 

laws and regulations. 

The telephone dialer must be wall mounted, in enclosed places and in a dry space.

For GSM module telephone dialers, avoid positions that can cause reduction of GSM 

fi

 eld strenght or 

its loss, or subject to electromagnetic noise. For this reason the dialer must not be placed on reinforced 

concrete walls, in basements, close to metal structures, near electric motors.

4.1 MOUNTING

4.1.1 OPENING

Open the telephone dialer as follows:

Remove the central plate in relief.

Remove the front lid, by unscrewing the cross screw placed in the front panel.

Remove the back lid, by rotating the two latches A to the open position. Help lid detaching from the 

support by inserting a screw driver in the four side block positions B.

Screw the provided antenna on the suitable connector C.

B

C

A

B

B

A

B

4.1.2 SIM INSERTION

For GSM module telephone dialer (1033/471 and 1033/472), it is necessary to perform the following 

preliminary operations:

1.   If necessary for the SIM and/or for the mobile network carrier, use a mobile to enable the SIM and 

disable its PIN before inserting the SIM in the GSM module). 

2.   Release the SIM holder, by pressing the lille button nearby, and slide it along its guides.

3.   Put the SIM in the holder, taking care contacts are visible, and put again the holder in its housing (when 

sliding the holder, SIM contacts must face the GSM module).

WARNING

: correct operation with USIM 3 is not ensured.

4.1.3 GSM FIELD CONTROL

 

For GSM module telephone dialer (1033/471 and 1033/472), it is necessary to check the GSM 

fi

 eld level 

in the precise point where it should be placed. To perform the test it is necessary to power up the dialer 

(for its connection, see paragraph about connections) and follow instructions in paragraph 

2.3.3 Telephone 

connection test – GSM 

fi

 eld test

The test result must be 

Excellent

 or 

Good

 at least. If results are different, it will be necessary to 

fi

 nd another 

installation place for the telephone dialer. If it is not possible to move the dialer, it would be suitable to move 

the antenna only, or change the antenna, as shows in the paragraph GSM antenna.

4.1.4 FIXING

The telephone dialer can be 

fi

 xed on a 3-modules 

fl

 ush mounting box or wall mounted.  

FIXING ON 3-MODULES FLUSH MOUNTING BOX

1.   Fix the back lid on a 3-modules box, using the provided screws. The correct 

fi

 xing direction is indicated 

by ALTO/TOP, written on the lid. In case of PSTN module telephone dialer mounting, open the pre-

fractured passage aperture for PSTN line. 

2.   On the dialer support, open the pre-fractured apertures for the passage of the required cables (power 

supply, inputs, output, etc.). In case of PSTN module telephone dialer mounting, break also the pre-

fractured passage aperture for PSTN line.

Содержание 1033/470

Страница 1: ...DS 1033 124 LBT 8355 Mod 1033 TELEPHONE DIALER Ref 1033 470 Ref 1033 471 Ref 1033 472...

Страница 2: ...4 user defined recordable alarm messages 4 telephone numbers associated to every input 12Vdc 10 15Vdc nominal power voltage Programmable number of call cycles 1 5 Programmable call delay GSM field tes...

Страница 3: ...elephone numbers associated to the alarmed input The message text is Urmet Security System Alarm on input X where X may be 1 2 3 or 4 and indicates the input in alarm state The other programmed voice...

Страница 4: ...pause one of the available commands is entered 1 2 3 4 or 9 the alarm call cycle is stopped see paragraph Alarm calls cycle interruption and the selected remote device is activated the dialer sends t...

Страница 5: ...ming procedure 301 Outputenablingfortelephoneconnection failure signalling failure on PSTN line or GSM field loss 0 signalling disabled 1 signalling enabled in case of failure the output relay is acti...

Страница 6: ...S messages sending 0 SMS messages enabled 1 SMS messages disabled 1 Various programming procedures 630 Follow me function 0 function disabled 1 function enabled 0 660 Password configuration for access...

Страница 7: ...associated to the message to be deleted followed by the button Start message recording after the acoustic signal Press again the button Recorded message 2 3 ADVANCED PROGRAMMING Theadvancedprogramming...

Страница 8: ...entering the value press button to confirm It is possible to check the parameter current configuration or if a value is correct by entering the respective parameter followed by button instead of butt...

Страница 9: ...irreversible and all configurations are deleted telephone numbers voice messages etc After a reset a new programming procedure is needed 3 MAINTENACE 3 1 CLEANING To clean the telephone dialer use a d...

Страница 10: ...it along its guides 3 Put the SIM in the holder taking care contacts are visible and put again the holder in its housing when sliding the holder SIM contacts must face the GSM module WARNING correct o...

Страница 11: ...of an alarm For the connection of the microphone used for environmental listening Ref 1061 003 use a twisted pair The line must not be longer than 100m in connection polarity must be respected The tam...

Страница 12: ...5mm2 section cable Max distance from inputs activation contacts IN1 IN2 IN3 IN4 to the PSTN GSM dialer 150m with 0 5mm2 section cable Max distance from PSTN GSM dialer output relay to KLIMAT ZOOM chro...

Страница 13: ...ef 39 011 24 00 000 RIC AUT Fax 39 011 24 00 300 323 Area tecnica servizio clienti 39 011 23 39 810 Fabbricato da Urmet Electronics Limited un azienda del gruppo Urmet Made in PRC Manufactured by Urme...

Отзывы: