urmet domus 1033/470 Скачать руководство пользователя страница 4

6

DS1033-124

7

DS1033-124

1.3.2 REMOTE MANAGEMENT

With a DTMF telephone it is possible to perform a remote management of devices connected to the dialer 

relay output. In detail it is possible to:

Activate and deactivate Urmet 1430/3 or Simon Urmet Ref. 10632 and 10632.B thermostats.

Con

fi

 gure the output relay state (relay excited or not excited).

It is also possible to activate the environmental listening function. In order to use this function, the

Ref. 1061/003 voice module (optional) must be installed. When this function is active, it is possible to listen 

for 1 minute what happens in the environment where the “voice module” is placed. In this way it is possible 

to understand off-site what is happening in that room.

To activate the remote management perform as follows:

User action

Dialer answer

(signal and voice message)

1

Digit the dialer telephone number

“Good morning, enter the password followed by 

button #”

2

Perform authentication procedure by 

entering the password, followed by button 

#

If the password is accepted:

“Correct password, programming procedure 

enabled”

If the password is not accepted:

“Wrong password”

 

3

Send the desired command by digiting:

1 = Thermostat power up

2 = Thermostat power off

3 = Relay closing

4 = Relay opening

9 = Environmental listening activation

0 = Telephone connection closing

Beep 

Thermostat activated

Beep

 Thermostat deactivated

Beep

 Output activated

Beep

 Output deactivated

Beep

 Environmental listening activated

Beep

, then the telephone connection is closed

If a wrong command is entered (for example by pressing the buttons 5, 6, 7 or 8), the dialer will answer with 

a long beep and the voice message 

Invalid code, enter again

.

It is possible to send several commands in sequence until the connection is active, i.e. until the command 0 

is sent. For example, it is possible to close the relay and then open it again after 30 seconds, or extend the 

environmental listening time, by sending a new command 9 within 60 seconds.

In case of inactivity for more than one minute, i.e. for over one minute any button has not been pressed, the 

dialer automatically closes the telephone connection in progress (the relay state does not change). 

The remote management is also active during alarm calls. If, while receiving an alarm call, during a pause, 

one of the available commands is entered (1, 2, 3, 4 or 9) the alarm call cycle is stopped (see paragraph 

Alarm calls cycle interruption) and the selected remote device is activated; the dialer sends the programmed 

answer (signal and voice message).

1.3.3 CALL DIVERSION FUNCTION

The telephone number associated during the programming procedure to the call diversion function 

(parameter 100) is always called as 

fi

 rst number for any alarm event (all the inputs and tamper). This means 

that it is called in addition to the telephone numbers programmed for the alarm in progress and before 

them. 

The call diversion function must be specially enabled during the programming procedure (parameter 630). 

Warning

: if the telephone number associated to the call diversion function is the only programmed number, 

i.e. all the other telephone numbers are empty, in case of an alarm it will be called also if the call diversion 

function is disabled.

2. PROGRAMMING

2.1 PROGRAMMING PROCEDURE

To perform the programming procedure, the dialer must be in standby, i.e. no alarm events, alarm call cycle 

or remote management must be active. To activate the programming procedure perform as follows:

1. Connect a DTMF telephone to the suitable dialer RJ12 socket.

2. Pick up the handset and press the programming button. The dialer will answer with “Good morning, 

enter 

the password followed by button hash #

”.

3.   Enter the access password (default 000000) followed by the button 

. Every time a button is pressed, 

the dialer sends a con

fi

 rmation beep.

4.   If the entered password is correct, the dialer answers with the voice message Correct password, 

Programming procedure enabled

; otherwise is received the message 

Wrong password

 and the 

password must be entered again. 

5.   After the password has been accepted, it is possible to con

fi

 gure the parameters. The con

fi

 guration 

sequence is not important.

If is entered a not valid parameter or value, the device answers with the voice message 

Not valid, enter 

again

.

To program the parameters digit the codes on the telephone keypad in the following format:

PARAMETER CODE + 

 

 

(enables the parameter con

fi

 guration) 

VALUE + 

 

 

 

(value assignment to the parameter) 

To check the correct parameter con

fi

 guration, digit:

PARAMETER CODE + 

 

Every time the button 

 is pressed, the dialer sends a voice message to con

fi

 rm the parameter or the 

value just entered. Before entering a value, wait until the voice message is completed.

To end the programming procedure, hang up the handset. 

Содержание 1033/470

Страница 1: ...DS 1033 124 LBT 8355 Mod 1033 TELEPHONE DIALER Ref 1033 470 Ref 1033 471 Ref 1033 472...

Страница 2: ...4 user defined recordable alarm messages 4 telephone numbers associated to every input 12Vdc 10 15Vdc nominal power voltage Programmable number of call cycles 1 5 Programmable call delay GSM field tes...

Страница 3: ...elephone numbers associated to the alarmed input The message text is Urmet Security System Alarm on input X where X may be 1 2 3 or 4 and indicates the input in alarm state The other programmed voice...

Страница 4: ...pause one of the available commands is entered 1 2 3 4 or 9 the alarm call cycle is stopped see paragraph Alarm calls cycle interruption and the selected remote device is activated the dialer sends t...

Страница 5: ...ming procedure 301 Outputenablingfortelephoneconnection failure signalling failure on PSTN line or GSM field loss 0 signalling disabled 1 signalling enabled in case of failure the output relay is acti...

Страница 6: ...S messages sending 0 SMS messages enabled 1 SMS messages disabled 1 Various programming procedures 630 Follow me function 0 function disabled 1 function enabled 0 660 Password configuration for access...

Страница 7: ...associated to the message to be deleted followed by the button Start message recording after the acoustic signal Press again the button Recorded message 2 3 ADVANCED PROGRAMMING Theadvancedprogramming...

Страница 8: ...entering the value press button to confirm It is possible to check the parameter current configuration or if a value is correct by entering the respective parameter followed by button instead of butt...

Страница 9: ...irreversible and all configurations are deleted telephone numbers voice messages etc After a reset a new programming procedure is needed 3 MAINTENACE 3 1 CLEANING To clean the telephone dialer use a d...

Страница 10: ...it along its guides 3 Put the SIM in the holder taking care contacts are visible and put again the holder in its housing when sliding the holder SIM contacts must face the GSM module WARNING correct o...

Страница 11: ...of an alarm For the connection of the microphone used for environmental listening Ref 1061 003 use a twisted pair The line must not be longer than 100m in connection polarity must be respected The tam...

Страница 12: ...5mm2 section cable Max distance from inputs activation contacts IN1 IN2 IN3 IN4 to the PSTN GSM dialer 150m with 0 5mm2 section cable Max distance from PSTN GSM dialer output relay to KLIMAT ZOOM chro...

Страница 13: ...ef 39 011 24 00 000 RIC AUT Fax 39 011 24 00 300 323 Area tecnica servizio clienti 39 011 23 39 810 Fabbricato da Urmet Electronics Limited un azienda del gruppo Urmet Made in PRC Manufactured by Urme...

Отзывы: