INPUTS
1
+ 12 V Power input
2
GND Power input
In these inputs is necessary to provide a stable supply, between 11V
and 14V C.C. from the alarm control panel or from an external 12V power
supply. This power is necessary to the operation of the LED
and for the logic of operation.
In the absence of voltage on this input, the logic part will continue
to operate, but the heater will not. For about 2 hours and 30 minutes, or until the temperature of the heat exchanger
(heating system) will allow, Fast 01 may produce fog. The maximum current drawn from UR Fog on this input is 230 mA.
3
RM Arming input
By connecting this input to positive, Fast 01 2C is armed, blue frontal led is switched on and when the machine reaches
proper temperature it means that it is ready for shooting.
4
SHOOT shooting input
Putting this input to positive, if Fast 01 2C is hot and armed, starts fog emission for the set time (see paragraph 11)
In case of alarm, when opening ARM input, the fog emission stops immediately, even if the time set wasn’t reached.
5
GND Negative reference
09
DESCRIPTION AND INPUT AND OUTPUT CONNECTIONS
VERIFICATION OF BATTERIES AND BATTERY CASE
You need to replace the batteries:
- After one year of use
- Within expiration date printed on them
- When it is reported they are exhausted.
If the batteries run out, a sequence of acoustic signals will start as follows:
- 2 bip / minute exhausting batteries
- 3 bip / minute machine can’t shoot, battery too low
- 10 bip / minute batteries are missing absent or bad contact on the battery case, plug or cable interrupted.
Any anomaly of the batteries also causes the activation of “fault” output, useful to remotely signal a possible anomaly.
When discharged batteries are removed from battery case, the buzzer will sound a sequence of 10 bips per minute.
After re-inserting the batteries, it is suggested to wait at least for one minute, in order to verify that the sequence of beeps is
not repeated. If the sequence of beeps does not stop, you should verify the polarity of the batteries is correct and, in that
case, that thebatteries are in contact with the battery case. At this stage, it may be useful to use a tester.
It is necessary to use high quality alkaline batteries.
It is possible to use lithium batteries - ask information to your retailer.
When you close the door, the buzzer will sound to confirm the anti-tamper system is correctly closed.
SET
RESET TAMPER
P3
1
2
3
4
5
6
7
8
9
+12V
GND
In ARM
In SHOOTS
GND
EMPTY
FAULT
TAMPER
GND
INGRESSO PILE
OUTPUTS
6
EMPTY Empty cylinder output
This output (NPN Open Collector) closes towards negative direction when at least one of the two cylinders is empty.
7
FAULT Fault output
This output (NPN Open Collector) closes towards negative when there is a serious malfunction (such as expired
batteries,
fault of power supply or temperature control fault), which compromises the functioning of the device
and which requires a technical action. Fault signal due to supply absence has a delay of 20 minutes.
8
TAMPER Tamper output
This output (NPN Open Collector) closes towards negative direction when you open the door cylinders or when the
accelerometer detects a sudden movement (such as the detachment from the wall).
9
GND Negative reference
8