05
HOW TO ACTIVATE THE SYSTEM
The cylinders supplied with the equipment are intended to be used only for a vertical (standard)
installation. In case of horizontal installation, please refer to your authorized reseller/distributor
to get the appropriate cylinders. I’s necessary to insert the cylinders with the black plastic plug.
It is always recommended to fix the machine on a wall even when it is placed on a flat surface.
Always verify that the bracket or the support surface are suitable for the weight of the machine.
It is suggested not to install the machine behind walls in a limited closed area without a specific
ventilation to prevent a possible overheating.
In case of installation at the ceiling, it is recommended to use the specific optional bracket.
In case of installation on a wall it’s possible to ask for a 7 cm nozzle extension.
After removing the machine from the package, unscrew the screws that stop the right side panel and remove it. Pay
attention to the screw below on the left as it’s longer than the others, unscrew the anti-tamper screw from the internal part
and then the screws of the cover. Inside it is possible to see the front part of the electronic circuit, from here on called PCB.
It is recommended to install the fogging system Fast 01 2C vertically. If it is needed to install Fast 01 2C
horizontally, it is necessary to order a special machine prepared for such installation and strictly follow the
installation instructions.
ENGINE
CYLINDER
5