16-19 (57*)
32-39 (117*)
48-58 (174*)
64-77 (231*)
80-96 (288*)
96-116 (348*)
112-135 (405*)
128-154 (462*)
144-173 (519*)
161-193 (579*)
177-212 (636*)
193-231 (693*)
209-250 (750*)
225-270 (810*)
241-289 (867*)
257-308 (924*)
273-327 (981*)
289-347 (1041*)
305-366 (1098*)
321-385 (1155*)
337-404 (1212*)
353-424 (1272*)
369-452 (1356*)
385-462 (1386*)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
2
4
401-482 (1446*)
417-501 (1503*)
433-520 (1560*)
449-539 (1617*)
465-559 (1677*)
482-578 (1734*)
498-597 (1791*)
514-616 (1848*)
530-635 (1386*)
546-655 (1965*)
562-674 (2022*)
578-693 (2079*)
594-713 (2139*)
610-732 (2196*)
626-751 (2253*)
642-770 (2310*)
658-790 (2370*)
674-809 (2427*)
690-828 (2484*)
722-867 (2601*)
706-874 (2622*)
738-886 (2658*)
754-905 (2715*)
770-924 (2772*)
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
786-944 (2832*)
803-963 (2889*)
819-982 (2946*)
835-1002 (3006*)
851-1021 (3063*)
867-1040 (3120*)
883-1059 (3177*)
899-1079 (3237*)
915-1098 (3294*)
931-1117 (3351*)
947-1136 (3408*)
963-1156 (3468*)
979-1175 (3525*)
995-1194 (3582*)
1011-1213 (3639*)
1027-1233 (3699*)
1043-1252 (3756*)
1059-1271 (3813*)
1075-1290 (3870*)
1091-1310 (2622*)
1107-1329 (3987*)
1124-1348 (4044*)
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
m³
to protect
Seconds
of emission
m³
to protect
m³
to protect
Seconds
of emission
Seconds
of emission
TABLE OF SHOOTING
FAST 01 2C
HxLxP-------- Height x Width x Depth of the area to protect
D------------- Density of the produced fog
V------------- Temperature and air pressure
R------------- Acceptable residue in case of saturation of V parameter
I-------------- Intensity of the surface light
(HxLxP) x D x V x R x I
To set the shooting time, after opening the cylinders compartment door as showed in
Paragraph 5, at the top of the PCB, you must put the jumper P3 in “setting” position.
Then, holding down the S1 “SET”, 3 LEDs on the front will start flashing and each flash is
equivalent to one second.If you press the button again, the shooting time is not added to the
one previously set, but will restart from zero.
N.B. The button in the cylinders compartment showed in next paragraph, is linked
to Set/Reset button.
Therefore, after setting shooting time, it is recommendable to place the P3 jumper in RESET
position (right side), in order to make this operation without removing the cover and avoid to
zero shooting time.
The following tables indicate the suggested fog emission in relation to the
number of seconds of shooting set in average condition of temperature,
air pressure and humidity.
*
Industrial standard as from other manufacturers
11
SHOOTING TIME SETTING
SET
RESET TAMPER
P3
SHOOTING TIME SETTING
N.B.
Before opening side door ensure that the control panel is set to “service”, so that the opening of “anti-sabotage or tamper” circuit does
not cause any shooting.
N.B.
To correctly dimension the machines it is needed to verify that the saturation of the area occurs in faster time than the one supposed
for the theft.
RECOMMENDED SHOOTING SECONDS ACCORDING TO THE VOLUME SPACE TO PROTECT (m
3
)
Systems FAST 01 2C are able to produce fog for a maximum respectively 70 seconds per single shot. The maximum quantity of
10,7 ml/s allows to fill an area of about 1200 m
3
. There might be cases in which, due to specific characteristic of the location, nozzle type,
levels of temperature and air pressure, degree of the fog density and light in the target area, the shooting time can be increased. For
example, above 5 m of height the shooting time must be integrated and above 7 m , every additional meter should be considered as double.
10