background image

16-19 (57*)

32-39 (117*)
48-58 (174*)
64-77 (231*)
80-96 (288*)

96-116 (348*)

112-135 (405*)
128-154 (462*)
144-173 (519*)
161-193 (579*)
177-212 (636*)
193-231 (693*)
209-250 (750*)
225-270 (810*)
241-289 (867*)
257-308 (924*)
273-327 (981*)

289-347 (1041*)
305-366 (1098*)
321-385 (1155*)
337-404 (1212*)
353-424 (1272*)
369-452 (1356*)
385-462 (1386*)

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20
21
22
23

2

4

401-482 (1446*)
417-501 (1503*)
433-520 (1560*)
449-539 (1617*)
465-559 (1677*)
482-578 (1734*)
498-597 (1791*)
514-616 (1848*)
530-635 (1386*)
546-655 (1965*)
562-674 (2022*)
578-693 (2079*)
594-713 (2139*)
610-732 (2196*)
626-751 (2253*)
642-770 (2310*)
658-790 (2370*)
674-809 (2427*)
690-828 (2484*)
722-867 (2601*)
706-874 (2622*)
738-886 (2658*)
754-905 (2715*)
770-924 (2772*)

25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48

786-944 (2832*)
803-963 (2889*)
819-982 (2946*)

835-1002 (3006*)
851-1021 (3063*)
867-1040 (3120*)
883-1059 (3177*)
899-1079 (3237*)
915-1098 (3294*)
931-1117 (3351*)
947-1136 (3408*)
963-1156 (3468*)
979-1175 (3525*)
995-1194 (3582*)

1011-1213 (3639*)
1027-1233 (3699*)
1043-1252 (3756*)
1059-1271 (3813*)
1075-1290 (3870*)
1091-1310 (2622*)
1107-1329 (3987*)
1124-1348 (4044*)

49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70

m³ 

to protect

Seconds 

of emission

m³ 

to protect

m³ 

to protect

Seconds 

of emission

Seconds 

of emission

TABLE OF SHOOTING 

FAST 01 2C

HxLxP-------- Height x Width x Depth of the area to protect
D------------- Density of the produced fog
V------------- Temperature and air pressure
R------------- Acceptable residue in case of saturation of V parameter
I-------------- Intensity of the surface light

(HxLxP) x D x V x R x I

To set the shooting time, after opening the cylinders compartment door as showed in 

Paragraph 5, at the top of the PCB, you  must put the jumper P3 in “setting” position.

Then, holding down the S1 “SET”, 3 LEDs on the front will start  flashing and each flash is 

equivalent to one second.If you press the button again, the shooting time is not added to the 

one previously set, but will restart from zero.

N.B. The button in the cylinders compartment showed in next paragraph, is linked 

to Set/Reset button.

 

Therefore, after setting shooting time, it is recommendable to place the P3 jumper in RESET 

position (right side), in order to make this operation without removing the cover and avoid to 

zero shooting time. 

The following tables indicate the suggested fog emission in relation to the 

number of seconds of shooting set in average condition of temperature, 

air pressure and humidity.

Industrial standard as from other manufacturers

11

SHOOTING TIME SETTING

SET

RESET TAMPER

P3

SHOOTING TIME SETTING

N.B.

 Before opening side door ensure that the control panel is set to “service”, so that the opening of “anti-sabotage or tamper” circuit does  

        not cause any shooting.

N.B.

 To correctly dimension the machines it is needed to verify that the saturation of the area occurs in faster time than the one supposed        

        for the theft.

RECOMMENDED SHOOTING SECONDS ACCORDING TO THE VOLUME SPACE TO PROTECT (m

3

)

Systems FAST 01 2C are able to produce fog for a maximum respectively 70 seconds per single shot. The maximum quantity of 

10,7 ml/s allows to fill an area of about 1200 m

3

. There might be cases in which, due to specific characteristic of the location, nozzle type, 

levels of temperature and air pressure, degree of the fog density and light in the target area, the shooting time can be increased. For 

example, above 5 m of height the shooting time must be integrated and above 7 m , every additional meter should be considered as double. 

10

Содержание FAST 01 2C

Страница 1: ...FAST FAST 01 2C INSTALLATION AND USE MANUAL Installation and use manual model FAST 01 110 230 V rev 22 08 2021 Page 1 of 20 ENGLISH MANUAL ...

Страница 2: ... page 7 08 Alcaline batteries page 7 09 Description and input and output connections page 8 10 Front LEDs page 9 11 Shooting time setting page 10 12 Connection example page 11 13 nstallation and cylinders exchange page 13 14 Maintenance page 14 15 Faults and possible solutions page 15 16 Reset from fault condition page 17 17 Warranty page 18 18 Maintenance and operations page 19 The conditions of ...

Страница 3: ...not guaranteed by the manufacturer the use of UR Fog system in the presence of objects that may be damaged anyway by the contact with substances based on glycol water and alcohol Any employee or worker that may be exposed to fog must be warned in advance and must be checked for any allergy to the substances listed above At the date of printing of this manual it has never been pointed out any probl...

Страница 4: ...nds from the point where the machine is installed 14 Setting the shooting time interval between the minimum and maximum shown in the shooting table avoid overshooting even if the produced fog is dry and generally doesn t leave residue A shot that goes far beyond the recommended seconds can create a residue problems in the room 15 UR Fog continues to be effective for up to 2 hours and 30 minutes wi...

Страница 5: ...prevent a possible overheating In case of installation at the ceiling it is recommended to use the specific optional bracket In case of installation on a wall it s possible to ask for a 7 cm nozzle extension After removing the machine from the package unscrew the screws that stop the right side panel and remove it Pay attention to the screw below on the left as it s longer than the others unscrew ...

Страница 6: ...2 X 300 w 540 W about 2 5 hours 60 W 500 mA while shooting 60 mA in stand by 12 months with 10 shots Tamper screw Accelerometer Industrial standard as from other manufacturers FAST 01 2C Loosened ferrule can cause dropping Do not disconnect the machine immediately after the shot Change batteries every year Change the cylinder as soon as the empty signal appears WARNING The empty signal does not me...

Страница 7: ...leted the installation It is necessary to connect the ground terminal The machine has to be connected to the power supply through a disconnecting device that has to brake both connections and must be thermo magnetic switch IF YOU NEED TO REPLACE THE FUSE USE THE ONE WITH EXACTLY SAME SPECIFICATIONS IF YOU HAVE DOUBTS ASK TO YOUR AUTHORIZED DEALER 1 Phase 220V 110V 2 Neutral 220V 110V 3 Ground conn...

Страница 8: ...the battery case plug or cable interrupted Any anomaly of the batteries also causes the activation of fault output useful to remotely signal a possible anomaly When discharged batteries are removed from battery case the buzzer will sound a sequence of 10 bips per minute After re inserting the batteries it is suggested to wait at least for one minute in order to verify that the sequence of beeps is...

Страница 9: ...ou to clearly see the direction and keep it in place while tightening To screw and unscrew the nozzle you should use a pair of pliers in good condition to avoid damaging the plating Do not overscrew the nozzle it is sufficient that the Teflon nozzle does not move Do not flow directly on objects or walls less than 2 meters away or to the floor if it is installed at a height lower than 2 50 meters D...

Страница 10: ...PCB you must put the jumper P3 in setting position Then holding down the S1 SET 3 LEDs on the front will start flashing and each flash is equivalent to one second If you press the button again the shooting time is not added to the one previously set but will restart from zero N B The button in the cylinders compartment showed in next paragraph is linked to Set Reset button Therefore after setting ...

Страница 11: ...all manufacturers of Fog Cannons the number of shooting seconds must be reduced by half The diagrams and examples below are intended to provide only for a better understanding of the operation of the inputs outputs None of the diagrams below represents the single scheme to perform as in respect of the reference standard there are specific indications and only using all inputs and outputs on the PC...

Страница 12: ...UR Fog S r l Via Toscana 38 10099 San Mauro T se Torino Italy N B Ask for the PDF module writing to support urfog com ...

Отзывы: