background image

02

INTRODUCTION OF THE PRODUCT

Thank you for purchasing UR Fog product.

The great patented technological innovations such as the liquid injection system, the disposable cylinders, the fact that they 
don’t need to be refilled, the ecological and economic system for the complete emptying of the cylinders, together with the 
heating system, all of them make the FAST fog generators the best fog devices with the best performance in the security 
market.

Reliable

: There are no high pressure pumps which lose fluid or tend to stop working.

 

 There are no high pressure pumps that must be tested periodically. 

 

 UR Fog double cylinders technology is guaranteed to work in any condition.

Competitive

: Complete use of cylinders liquid avoiding any waste of liquid thanks to pressure control.

 

       Low power consumption, fast and powerful.

Simple

: Machine easy to install and able to be integrated to any existing alarm system. 

03

CONDITIONS OF USE AND WARNINGS

The fog generated by UR Fog does not create particular problems or injuries for a human being for a short stay in a fogged 
room if the system is used according to the manufacturer’s recommendations. 
Generated fog is certified as safe for people and animals from an authorized international certification company and is proved 
that it does not leave any residual. 
UR Fog systems are certified respecting  European laws and regulations. Any certifications required in specific countries are a 
responsibility of the distributor of that specific country. 
The documents related to certifications can be requested by mail to 

[email protected]

.  

It is not guaranteed by the manufacturer the use of UR Fog system in the presence of objects that may be damaged  anyway 
by the contact with substances based on glycol, water and alcohol. Any employee or worker that may be exposed to fog must 
be warned in advance and must be checked for any allergy to the substances listed above. At the date of printing of this 
manual it has never been pointed out any problem related to any allergy. 
UR Fog is in no way responsible for any damage or condition of use that has not been required and specifically approved by 
any specific written request prior to the installation of its products. 
For fog fluid please refer to UR Fog fluid safety data sheet published on the website and carefully read it at 

www.urfog.com

.  

Contact a doctor if for any reason you swallow fog fluid or if after contact with eyes or skin you have any kind of reaction, 
and in any case wash it immediately with water and soap. Do never  stay for a long time in a room filled with fog. 
Do not use charged cylinders that are not the ones suggested by UR Fog and never try to recharge them, they are made for 
a single use. Follow your national rules for the dispose of empty cylinders. 
Keep UR Fog cylinders out of reach of babies and animals. The nozzle may be hot and touching it may cause burns. 
Do not look directly into the nozzle. 
Never use UR Fog products for any purpose that is not related to protection from thief or robbery (the choice of the conditions 
of use in case of robbery will be suggested by your security consultant). 
Never use different fog fluids or add any other substance into the cylinders. 
Do not use or keep charged UR Fog machines in vehicles and do never transport UR Fog before 24 hours since it has been 
shut off. During transport it must be not armed.

3

Содержание FAST 01 2C

Страница 1: ...FAST FAST 01 2C INSTALLATION AND USE MANUAL Installation and use manual model FAST 01 110 230 V rev 22 08 2021 Page 1 of 20 ENGLISH MANUAL ...

Страница 2: ... page 7 08 Alcaline batteries page 7 09 Description and input and output connections page 8 10 Front LEDs page 9 11 Shooting time setting page 10 12 Connection example page 11 13 nstallation and cylinders exchange page 13 14 Maintenance page 14 15 Faults and possible solutions page 15 16 Reset from fault condition page 17 17 Warranty page 18 18 Maintenance and operations page 19 The conditions of ...

Страница 3: ...not guaranteed by the manufacturer the use of UR Fog system in the presence of objects that may be damaged anyway by the contact with substances based on glycol water and alcohol Any employee or worker that may be exposed to fog must be warned in advance and must be checked for any allergy to the substances listed above At the date of printing of this manual it has never been pointed out any probl...

Страница 4: ...nds from the point where the machine is installed 14 Setting the shooting time interval between the minimum and maximum shown in the shooting table avoid overshooting even if the produced fog is dry and generally doesn t leave residue A shot that goes far beyond the recommended seconds can create a residue problems in the room 15 UR Fog continues to be effective for up to 2 hours and 30 minutes wi...

Страница 5: ...prevent a possible overheating In case of installation at the ceiling it is recommended to use the specific optional bracket In case of installation on a wall it s possible to ask for a 7 cm nozzle extension After removing the machine from the package unscrew the screws that stop the right side panel and remove it Pay attention to the screw below on the left as it s longer than the others unscrew ...

Страница 6: ...2 X 300 w 540 W about 2 5 hours 60 W 500 mA while shooting 60 mA in stand by 12 months with 10 shots Tamper screw Accelerometer Industrial standard as from other manufacturers FAST 01 2C Loosened ferrule can cause dropping Do not disconnect the machine immediately after the shot Change batteries every year Change the cylinder as soon as the empty signal appears WARNING The empty signal does not me...

Страница 7: ...leted the installation It is necessary to connect the ground terminal The machine has to be connected to the power supply through a disconnecting device that has to brake both connections and must be thermo magnetic switch IF YOU NEED TO REPLACE THE FUSE USE THE ONE WITH EXACTLY SAME SPECIFICATIONS IF YOU HAVE DOUBTS ASK TO YOUR AUTHORIZED DEALER 1 Phase 220V 110V 2 Neutral 220V 110V 3 Ground conn...

Страница 8: ...the battery case plug or cable interrupted Any anomaly of the batteries also causes the activation of fault output useful to remotely signal a possible anomaly When discharged batteries are removed from battery case the buzzer will sound a sequence of 10 bips per minute After re inserting the batteries it is suggested to wait at least for one minute in order to verify that the sequence of beeps is...

Страница 9: ...ou to clearly see the direction and keep it in place while tightening To screw and unscrew the nozzle you should use a pair of pliers in good condition to avoid damaging the plating Do not overscrew the nozzle it is sufficient that the Teflon nozzle does not move Do not flow directly on objects or walls less than 2 meters away or to the floor if it is installed at a height lower than 2 50 meters D...

Страница 10: ...PCB you must put the jumper P3 in setting position Then holding down the S1 SET 3 LEDs on the front will start flashing and each flash is equivalent to one second If you press the button again the shooting time is not added to the one previously set but will restart from zero N B The button in the cylinders compartment showed in next paragraph is linked to Set Reset button Therefore after setting ...

Страница 11: ...all manufacturers of Fog Cannons the number of shooting seconds must be reduced by half The diagrams and examples below are intended to provide only for a better understanding of the operation of the inputs outputs None of the diagrams below represents the single scheme to perform as in respect of the reference standard there are specific indications and only using all inputs and outputs on the PC...

Страница 12: ...UR Fog S r l Via Toscana 38 10099 San Mauro T se Torino Italy N B Ask for the PDF module writing to support urfog com ...

Отзывы: