04
INSTALLATIONS TIPS TO INSTALL FOGGING SYSTEMS
Please observe the following instructions for installing UR Fog:
1.
This appliance is not intended for use by person (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
2.
Children should be supervised to ensure that they do not play with this appliance.
3.
The machine must be installed avoiding to obstruct escape routes.
4.
Verify the fog does not limit the visibility near: stairs, landings, moving objects that may cause:
falls down, injuries or any damage to persons.
5.
Do not look directly into the nozzle. Do not add any other substance into the cylinders.
6.
The nozzle may reach high temperatures, touch it may cause burns.
7.
When UR Fog produces fog avoid staying closer than 1 meter from the machine.
8.
When UR Fog is armed avoid staying closer than 50 cm from the nozzle.
9.
Before testing UR Fog, remember to report it in advance to the firefighters in your area to avoid false alarms.
10.
Remember to put warning labels about the presence of UR Fog on the windows.
11.
Report its installation to the firefighters in your area and eventually to other institutions if needed.
12.
It is necessary to add an external switch to separate the fog generator from the alarm system and it should be
activated before the maintenance to avoid that input tests, for example, can activate the fog generator.
13.
Never direct the fog jet towards an object or a wall less than 2 meters away and if possible increase the suggested
minimum distance. Thanks to the power of the jet, UR Fog reaches and exceeds more than 10 meters away in the first
3 seconds from the point where the machine is installed.
14.
Setting the shooting time interval between the minimum and maximum shown in the shooting table, avoid
“overshooting” even if the produced fog is dry and generally doesn’t leave residue. A shot that goes far beyond the
recommended seconds can create a residue problems in the room.
15.
UR Fog continues to be effective for up to 2 hours and 30 minutes without 220V or 110V main power thanks to the
insulation system which maintains the temperature in the heating system.
16.
Install at an height of about 2,5 meters not to let it be reached, avoiding possible tampering.
17.
Install with a maximum inclination of 20°.
18.
Do not move the machine when it is still hot.
19.
The main body of UR Fog, which has the heating system enclosed inside a metal frame, should not be opened unless
by specific and authorized service centers. Do not open and touch for any reason the insulation before 24 hours
UR Fog has been shut off. The internal part may reach really high temperature.
20.
Do not activate the UR Fog machine before the installation is completed.
21.
Insert the cylinders as the last procedure and verify the anti-tampering function.
22.
When the installation is finished, always test the system.
23.
From the moment of UR Fog activation, at least one hour is necessary to reach the minimum temperature needed for
the fog shooting.
24.
Install UR Fog avoiding any obstacles in front of it which can prevent the spreading of the fog.
25.
The external temperature of UR Fog can change from room temperature to 50 °C.
26.
The tip of a stranded conductor should not be soft-soldered where the conductor is subjected to contact pressure.
27.
The UR Fog machine should not be exposed to water spray or dripping.
28.
Request to UR Fog or its distributors to take part in courses for installers to ensure the optimal installation of
the equipment.
29.
The content of the bags is mechanically predetermined and can be subject to vari/- 10%
4