background image

04

INSTALLATIONS TIPS TO INSTALL FOGGING SYSTEMS

Please observe the following instructions for installing UR Fog:

  1.

 This appliance is not intended for use by person (including children) with reduced physical, sensory or 

      mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 

      instruction concerning use of the appliance by a person responsible for their safety.

  2.

 Children should be supervised to ensure that they do not play with this appliance.

  3.

 The machine must be installed avoiding to obstruct escape routes.

  4.

 Verify the fog does not limit the visibility near: stairs, landings, moving objects that may cause: 

      falls down, injuries or any damage to persons.

  5.

 Do not look directly into the nozzle. Do not add any other substance into the cylinders.

  6.

 The nozzle may reach high temperatures, touch it may cause burns.

  7.

 When UR Fog produces fog avoid staying closer than 1 meter from the machine.

  8.

 When UR Fog is armed avoid staying closer than 50 cm from the nozzle.

  9.

 Before testing UR Fog, remember to report it in advance to the firefighters in your area to avoid false alarms.

10.

 Remember to put warning labels about the presence of UR Fog on the windows.

11.

 Report its installation to the firefighters in your area and eventually to other institutions if needed.

12.

 It is necessary to add an external switch to separate the fog generator from the alarm system and it should be  

      activated before the maintenance to avoid that input tests, for example, can activate the fog generator.

13.

 Never direct the fog jet towards an object or a wall less than 2 meters away and if possible increase the suggested  

      minimum distance. Thanks to the power of the jet, UR Fog reaches and exceeds more than 10 meters away in the first  

      3 seconds from the point where the machine is installed.

14.

 Setting the shooting time interval between the minimum and maximum shown in the shooting table, avoid 

      “overshooting” even if the produced fog is dry and generally doesn’t leave residue. A shot that goes far beyond the  

      recommended seconds can create a residue problems in the room.

15.

 UR Fog continues to be effective for up to 2 hours and 30 minutes without 220V or 110V main power thanks to the  

      insulation system which maintains the temperature in the heating system.

16.

 Install at an height of about 2,5 meters not to let it be reached, avoiding possible tampering.

17.

 Install with a maximum inclination of 20°.

18.

 Do not move the machine when it is still hot.

19.

 The main body of UR Fog, which has the heating system enclosed inside a metal frame, should not be opened unless  

      by specific and authorized service centers. Do not open and touch for any reason the insulation before 24 hours 

      UR Fog has been shut off. The internal part may reach really high temperature.

20.

 Do not activate the UR Fog machine before the installation is completed.

21.

 Insert the cylinders as the last procedure and verify the anti-tampering function. 

22.

 When the installation is finished, always test the system.

23.

 From the moment of UR Fog activation, at least one hour is necessary to reach the minimum temperature needed for  

      the fog shooting.

24.

 Install UR Fog avoiding any obstacles in front of it which can prevent the spreading of the fog.

25.

 The external temperature of UR Fog can change from room temperature to 50 °C.

26.

 The tip of a stranded conductor should not be soft-soldered where the conductor is subjected to contact pressure.

27.

 The UR Fog machine should not be exposed to water spray or dripping.

 28.

 Request to UR Fog or its distributors to take part in courses for installers to ensure the optimal installation of  

 

      the equipment.

 29.

 The content of the bags is mechanically predetermined and can be subject to vari/- 10%

4

Содержание FAST 01 2C

Страница 1: ...FAST FAST 01 2C INSTALLATION AND USE MANUAL Installation and use manual model FAST 01 110 230 V rev 22 08 2021 Page 1 of 20 ENGLISH MANUAL ...

Страница 2: ... page 7 08 Alcaline batteries page 7 09 Description and input and output connections page 8 10 Front LEDs page 9 11 Shooting time setting page 10 12 Connection example page 11 13 nstallation and cylinders exchange page 13 14 Maintenance page 14 15 Faults and possible solutions page 15 16 Reset from fault condition page 17 17 Warranty page 18 18 Maintenance and operations page 19 The conditions of ...

Страница 3: ...not guaranteed by the manufacturer the use of UR Fog system in the presence of objects that may be damaged anyway by the contact with substances based on glycol water and alcohol Any employee or worker that may be exposed to fog must be warned in advance and must be checked for any allergy to the substances listed above At the date of printing of this manual it has never been pointed out any probl...

Страница 4: ...nds from the point where the machine is installed 14 Setting the shooting time interval between the minimum and maximum shown in the shooting table avoid overshooting even if the produced fog is dry and generally doesn t leave residue A shot that goes far beyond the recommended seconds can create a residue problems in the room 15 UR Fog continues to be effective for up to 2 hours and 30 minutes wi...

Страница 5: ...prevent a possible overheating In case of installation at the ceiling it is recommended to use the specific optional bracket In case of installation on a wall it s possible to ask for a 7 cm nozzle extension After removing the machine from the package unscrew the screws that stop the right side panel and remove it Pay attention to the screw below on the left as it s longer than the others unscrew ...

Страница 6: ...2 X 300 w 540 W about 2 5 hours 60 W 500 mA while shooting 60 mA in stand by 12 months with 10 shots Tamper screw Accelerometer Industrial standard as from other manufacturers FAST 01 2C Loosened ferrule can cause dropping Do not disconnect the machine immediately after the shot Change batteries every year Change the cylinder as soon as the empty signal appears WARNING The empty signal does not me...

Страница 7: ...leted the installation It is necessary to connect the ground terminal The machine has to be connected to the power supply through a disconnecting device that has to brake both connections and must be thermo magnetic switch IF YOU NEED TO REPLACE THE FUSE USE THE ONE WITH EXACTLY SAME SPECIFICATIONS IF YOU HAVE DOUBTS ASK TO YOUR AUTHORIZED DEALER 1 Phase 220V 110V 2 Neutral 220V 110V 3 Ground conn...

Страница 8: ...the battery case plug or cable interrupted Any anomaly of the batteries also causes the activation of fault output useful to remotely signal a possible anomaly When discharged batteries are removed from battery case the buzzer will sound a sequence of 10 bips per minute After re inserting the batteries it is suggested to wait at least for one minute in order to verify that the sequence of beeps is...

Страница 9: ...ou to clearly see the direction and keep it in place while tightening To screw and unscrew the nozzle you should use a pair of pliers in good condition to avoid damaging the plating Do not overscrew the nozzle it is sufficient that the Teflon nozzle does not move Do not flow directly on objects or walls less than 2 meters away or to the floor if it is installed at a height lower than 2 50 meters D...

Страница 10: ...PCB you must put the jumper P3 in setting position Then holding down the S1 SET 3 LEDs on the front will start flashing and each flash is equivalent to one second If you press the button again the shooting time is not added to the one previously set but will restart from zero N B The button in the cylinders compartment showed in next paragraph is linked to Set Reset button Therefore after setting ...

Страница 11: ...all manufacturers of Fog Cannons the number of shooting seconds must be reduced by half The diagrams and examples below are intended to provide only for a better understanding of the operation of the inputs outputs None of the diagrams below represents the single scheme to perform as in respect of the reference standard there are specific indications and only using all inputs and outputs on the PC...

Страница 12: ...UR Fog S r l Via Toscana 38 10099 San Mauro T se Torino Italy N B Ask for the PDF module writing to support urfog com ...

Отзывы: