Specifications
Installation Manual
Page 40
560-0405-00 Rev –
December 14, 2001
© 2001 by UPS Aviation Technologies Inc.
14.107”
5.04”
7.64”
Figure 13 – AT7000 Dimensions
7.3
Environmental
The AT7000 Mode S Transponder is designed and tested to meet appropriate categories
of RTCA/DO-xxx. The Environmental Qualification Form is included in Section 10.
Operating temperature...............................-20
°
C to +70
°
C
Storage temperature ..................................-55
°
C to +85
°
C
Temperature variation ...............................5
°
C per minute (minimum)
Humidity ...................................................95% RH at 65°C for 6 hours (10 day cycle)
Maximum altitude .....................................55,000 feet
Cooling......................................................The unit can utilize external cooling air in
accordance with ARINC 600, ARINC 404
or operate in convection cooled environ-
ments.
7.4
Transponder Performance
TSO ................................................................TSO-C112
TSO Class ......................................................CL 2A7, 121, 011
Warm-up ........................................................None required
Receiver Frequency........................................1030 MHz
Sensitivity (MTL) ..........................................-72 dBm +/- 1 dB
Dynamic Range..............................................>50 dB
Side Lobe Suppression...................................2 pulse (P1, P2), -60 dBm
Transmitter Frequency...................................1090 MHz +/- 120 kHz