Installation Manual
Specifications
560-0405-00 Rev –
December 14, 2001
Page 39
© 2001 by UPS Aviation Technologies Inc.
Section 7 -
Specifications
This section includes detailed electrical, physical, environmental, and performance speci-
fications for the AT7000.
7.1
Electrical
Power Requirements (28VDC)
Operating Voltage ....................18 to 32.2VDC; 28 VDC typical
Power Consumption:
Standby Mode ..........................................20 Watts
Active Mode (typical load) ......................30 Watts
Active Mode (maximum load ..................60 Watts
Power Requirements (115V, 400 Hz):
Operating Voltage .....................90 to 135VAC, 400 Hz; 115VAC, 400 Hz typical
Power Consumption:
Standby Mode ..........................................24 Watts
Active Mode (typical load) ......................36 Watts
Active Mode (maximum load ..................65 Watts
7.2
Physical
ARINC 600 4MCU Type 2 Connector; (Polarization code “05”)
Height ...................................................7.64"
Width ....................................................5.04"
Depth ....................................................14.107"
AT7000 Weight ...................................9.6 lbs.