Motor Controller Dip Switch Settings
Section 3 - Troubleshooting
Page 3-4
114101-000 X26 Ultra Narrow - Service Manual
3-4 M
OTOR
C
ONTROLLER
D
IP
S
WITCH
S
ETTINGS
Figure 3-2:
Controller Dip Switch
D
E F A U L T
D
I P
S
W I T C H
S
E T T I N G S
The table shows the default dip switch settings on the control-
ler box when the machine leaves the factory.
A
D J U S T E D
D
I P
S
W I T C H
S
E T T I N G S
The following adjustments may be made to the dip switch settings.
C
REEP
S
PEED
Switches 3 & 4 determine the elevated “creep” speed. If the machine does not operate at the specified speed at
the default settings, use the following table to adjust the dip switch settings
.
D
ECELERATION
T
IME
Switches 5 & 6 determine the deceleration time. Switch 5 is for the deceleration rate while the platform is
lowered. Switch 6 is for the elevated rate.
1
2
3
4
5
6
7
8
MX15/19
OFF
ON
OFF
ON
OFF
ON
OFF
ON
SL20
ON
OFF
OFF
ON
OFF
ON
OFF
ON
TM12
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
X20N
ON
OFF
OFF
ON
OFF
ON
OFF
ON
X20W
ON
OFF
OFF
ON
OFF
ON
OFF
ON
X26UN
ON
ON
OFF
OFF
OFF
ON
OFF
ON
X26/32
ON
ON
OFF
ON
OFF
OFF
OFF
ON
3
4
1(slowest)
OFF
OFF
2
ON
OFF
3 (default)
OFF
ON
4 (fastest)
ON
ON
DECEL
5
6
0.24 sec.
OFF
OFF
1.27 sec.
ON
ON