Section 2 - Service and Repair
Batteries
114101-000 X26 Ultra Narrow - Service Manual
Page 2-17
B
A T T E R Y
R
E P L A C E M E N T
R
EMOVAL
Figure 2-11:
Battery Installation
1. Turn the Chassis Key Switch to the OFF position
and push the Chassis and Platform Emergency
Stop Switches down to the OFF position.
NOTE:
If switches are ON, a spark will occur at the ground
terminal which could cause an explosion if hydrogen gas
or fuel vapors are present.
2. Open the power module.
3. Disconnect battery pack connector.
4. Disconnect the battery negative (–) lead.
IMPORTANT: Disconnect the battery negative (–) lead first.
5. Disconnect the remaining battery leads.
6. Lift the batteries out of the module.
I
NSTALLATION
Battery cables must be installed as shown in
Figure 2-11.
IMPORTANT: Connect the battery negative (–) lead last.
1. Verify that the Chassis Key Switch and the Chas-
sis and Platform Emergency Stop Switches are in the OFF position.
2. Place the batteries into the power module.
3. Connect the battery to battery leads.
4. Connect the battery positive (+) lead.
5. Connect the battery negative (–) lead.
6. Connect the battery pack connector.
3
4
2
1
5
1. Power Module
2. Negative Battery Lead
3. Positive Battery Lead
4. Battery to Battery Leads
5. Battery Pack Connector