Blocking the Elevating Assembly
Section 2 - Service and Repair
Page 2-8
114101-000 X26 Ultra Narrow - Service Manual
2-3 B
LOCKING
THE
E
LEVATING
A
SSEMBLY
W A R N I N G
!
!
Never perform service while the platform is elevated without first blocking the elevating assembly.
DO NOT stand in the elevating assembly area while deploying or storing the maintenance brace.
Figure 2-2:
Maintenance Brace
I
NSTALLATION
1. Park the machine on a firm, level surface.
2. Pull Chassis Emergency Stop Switch to the ON
position.
3. Pull Platform Emergency Stop Switch to the ON
position.
4. Turn and hold the Chassis Key Switch to CHASSIS.
5. Push the Chassis Lift/Lower Switch to LIFT to ele-
vate the platform until the maintenance brace can
be rotated to the vertical position.
6. From the front of the machine, lift the maintenance
brace from its stowed position. Rotate upward and
outward, then down until it is hanging vertically
below its attachment point.
7. Lower the platform by pushing the Chassis Lift/Lower Switch to LOWER and gradually lower the plat-
form until the maintenance brace is supporting the platform.
S
TORAGE
1. Using the Chassis Controls, gradually elevate the platform until the maintenance brace is clear.
2. Rotate the maintenance brace outward and upward over its attachment point until it rests in the stowed
position.
3. Lower the platform by pushing the Chassis Lift/Lower Switch to LOWER to completely lower the plat-
form.
2-4 L
UBRICATION
Figure 2-3:
Lubrication Points
There are four lubrication points on the
machine - two on each steering pivot (see
Figure 2-3).
Lubricate the steering pivots every
125 hours or three months.
1. Deploy the maintenance brace (see
“Blocking the Elevating Assembly” on
page 2-8).
2. Clean the grease fittings and surrounding
area.
3. Using multipurpose grease in a grease
gun, pump the grease into the fitting until
grease just begins to appear at the edges
of the pivot.
4. Wipe off any excess grease.