Hydraulics
Section 2 - Service and Repair
Page 2-26
114101-000 X26 Ultra Narrow - Service Manual
E
M E R G E N C Y
L
O W E R I N G
V
A L V E
W A R N I N G
!
!
Never perform service while the platform is elevated without first blocking the elevating assembly.
DO NOT stand in the elevating assembly area while deploying or storing the maintenance brace.
Figure 2-20:
Emergency Lowering Valve
The Emergency Lowering
Valve is mounted on the
base of the lift cylinder. The
cable is routed;
• from the valve,
• along the elevating
assembly tube to the
front of the machine,
• through the cable
access hole to the rear
of the machine.
R
EPAIR
1. Deploy the maintenance
brace (see “Blocking the
Elevating Assembly” on
page 2-8).
2. Inspect the cable.
Replace if damaged.
3. Inspect the valve. Replace
if damaged.
4. Check for and clear any
blockage in the orifice.
Install the orifice with the
beveled side toward the
cylinder block.
5. Adjust the valve.
• At the cable mount,
adjust the cable cover to
stop the inner cable
when the valve is fully
open.
6. Store the maintenance brace and lower the platform.
2
5
5
6
1
4
3
3
1. Maintenance Brace
2. Cable
3. Valve
4. Orifice
5. Cable Mount
6. Cable Access Hole