Section 2 - Service and Repair
Controls
114101-000 X26 Ultra Narrow - Service Manual
Page 2-15
P
ROXIMITY
S
WITCH
A
DJUSTMENT
Figure 2-10:
Proximity Switch Adjustment
W A R N I N G
!
!
Never perform service while the platform
is elevated without first blocking the
elevating assembly.
DO NOT stand in the elevating assembly
area while deploying or storing the
maintenance brace.
1. Deploy the maintenance brace (see
“Blocking the Elevating Assembly” on
page 2-8).
2. Use a clamp to attach a straight
guide to the elevating assembly tube.
3. Measure the distance from the face
of the Proximity Switch to the side of
the guide that faces the elevating
assembly tube.
4. Turn the adjusting nuts to adjust to
within 4,76 mm to 6,35 mm (
3/16 in.
to 1/4 in.
).
5. Remove the clamp and guide and
repeat the test.
• If the test fails, the switch is defec-
tive and must be replaced.
1
4
(3/16 in. - 1/4 in.)
4,75 mm - 6,35 mm
3
2
1. Maintenance Brace
2. Guide
3. Proximity Switch
4. Adjustment Nuts