Section 2 - Service and Repair
Controls
114101-000 X26 Ultra Narrow - Service Manual
Page 2-11
L
E V E L
S
E N S O R
I
NTRODUCTION
The Level Sensor Is located near the front of the chassis between the elevating assembly sections, and is
covered with a protective metal box. It has three wires; red-power (24V in), black-ground, white-output
(24V out). To verify the sensor is working properly there are two LED's under the sensor; green indicates
the sensor is on (has power), red indicates the sensor is level and the white wire is 'hot' (24V out).
W A R N I N G
!
!
Never perform service while the platform is elevated without first blocking the elevating assembly.
DO NOT stand in the elevating assembly area while deploying or storing the maintenance brace.
L
EVEL
S
ENSOR
A
DJUSTMENT
Figure 2-7:
Level Sensor and Proximity Switch
1. Place machine on firm, level surface.
2. Use the Inclinometer (P/N: 10119-000-00) to ensure
that the Chassis is level from front to rear and side
to side.
3. Deploy the maintenance brace (see “Blocking the
Elevating Assembly” on page 2-8).
4. Remove the Level Sensor electrical box cover near
the front of machine.
5. Adjust the three leveling locknuts until the bubble is
centered in the circle on the attached bubble level.
6. Replace the Level Sensor electrical box cover.
7. Store the maintenance brace and lower the plat-
form.
1
3
4
2
1. Level Sensor Electrical Box Cover
2. Level Sensor
3. Proximity Switch
4. Height Limit Switch