10.5 OSMOSIS SYSTEM ERROR MESSAGES
BREAKDOWN
CAUSE
SOLUTION
Pressure transducer is damaged
Transducer / power card
connecting cable is damaged or
disconnected
Display no. 1 shows continuously
EO1 message
Osmosis power card is damaged
Apply to a
UNOX
qualified
technician for service
Liter-counter is damaged
Liter-counter / power card
connecting cable is damaged or
disconnected
Display no. 1 shows continuously
EO2 message
Osmosis power card is damaged
Apply to a
UNOX
qualified
technician for service
Display no. 1 shows continuously
EO3 message
Filters working limit reached
Apply to a
UNOX
qualified
technician for service
Display no. 1 shows continuously
EO4 message
Inlet water pressure is too low
Verificare che arrivi acqua
all’ingresso dell’osmosi
Oven / osmosis connecting cable
is damaged or disconnected
Display no. 1 shows continuously
EO5 message
Osmosis power card is damaged
Apply to a
UNOX
qualified
technician for service