background image

P a g e

 | 2

 
 

 

ÜKY/DUO Boiler User Manual 

 

INTRODUCTION

 

Thank you for choosing ÜNMAK ÜKY/DUO series solid fuel boiler. ÜNMAK ÜKY/DUO 

series boilers are produced with both automatic and manual feeding. 

Please read the user manual carefully before installing and operating your product 

and keep the user manual for the life of the product. Do not touch or mix any part 

of the product other than the places allowed in the user manual. 

The installation, maintenance and service of the boiler requires expert technical team. 

These operating instructions and regulations should be considered for the installation of the boiler, 

the  selection  of  the  appropriate  location  for  the  installation,  the  installation  of  the  boiler  water 

installation and the design of the chimney. 

ÜNMAK DUO Series boilers are high efficiency steel welded hot water boilers designed to burn solid 

fuel only. Coal with a diameter of 10-18 mm (sold in the market under the name of hazelnut coal), 

nutshell, cherry-cherry kernel, olive pomace, pellet etc. It is suitable for burning fuels. These boilers 

are  used  only  for  heating  installations,  not  directly  for  domestic  water  heating.  However,  it  can 

produce  hot  tap  water  with  the  help  of  a  boiler  or  heat  exchanger.  The  energy  required  for  the 

domestic water will be taken from the boiler energy. 

ÜNMAK DUO Series  boilers convert  the chemical energy of the  fuel in the fuel loading chamber to 

heat energy by combustion and load it on the water that is heating fluid. Excessive fuel build-up in 

the  combustion  chamber  by  keeping  the  feed  setting  overstated  will  result  in  energy  loss  and  will 

take longer to burn the fuel. 

The  combustion circuit, fan, feed auger  and system pump control are carried out  by the electronic 

control panel supplied with the boiler. 

ÜNMAK  DUO  Series  boilers  can  only  burn  granular  fuels  up  to  25  mm  in  diameter.  Since  the 

powdered fuels will fly inside the combustion chamber with the system fan, there will be no efficient 

combustion. Since powdered fuel will collect more moisture, it will even cause spiral blockage in the 

feed  screw.  Depending  on  the  calorific  values  of the  fuels, the  heat  passing  from  the  boiler  to  the 

water may exceed the declared values. 

 

 

 

 Your  user  manual  should  be  read  carefully  and  kept  with  the  warranty  certificate 

enclosed for the lifetime of the boiler. 

Содержание UKY/DUO 100

Страница 1: ...KY DUO Boiler User Manual NL SOY Yap Malzemeleri Sanayi ve Ticaret Ltd ti Pancar Organize Sanayi B lgesi 2 Etap No 2 Torbal ZM R Tel 444 35 32 Faks 0232 469 2412 www unmak com...

Страница 2: ...ONS 6 ELECTRICAL INSTALLATION INSTRUCTIONS 8 INFORMATION ABOUT COMBUSTION 10 BOILER FEATURES 12 RULES FOR HEATING INSTALLATION 15 CONTROL PANEL AND USER INTERFACE 19 STARTING UP 21 FUEL FEEDING STAND...

Страница 3: ...re used only for heating installations not directly for domestic water heating However it can produce hot tap water with the help of a boiler or heat exchanger The energy required for the domestic wat...

Страница 4: ...transportation rope through the forklift stands on the chassis and carrying the boiler with the help of a crane or hoist care should be taken not to damage the painted thin sheets of the boiler and t...

Страница 5: ...ble solution The door of the boiler room should not be opened directly to the escape staircase or general use staircase and must be opened to a common hall or corridor A threshold of at least 10 cm he...

Страница 6: ...dimensions The boiler room should be sized to provide the minimum dimensions given in the picture below While placing the boiler it is necessary to leave sufficient distance for the fuel to be added...

Страница 7: ...ver be used in chimney construction It should be plastered inside and outside and cylindrical pipe inserted into the rectangular chimney It should be ensured that fresh air always enters the area wher...

Страница 8: ...llation water flow rate and the boiler capacity and the 20 C difference between the boiler inlet and outlet water temperatures are not exceeded To minimize the completion of water lost in the installa...

Страница 9: ...te hot dip or c Solid copper rod should be made with electrodes Copper rod electrodes must be at least 1 5 m in diameter of 16 mm or at least 1 25 m in diameter of 20 mm and the earthing resistance of...

Страница 10: ...P a g e 9 KY DUO Boiler User Manual Control panel electrical connection diagram...

Страница 11: ...e flue to the atmosphere The material the way of construction and the connection of the chimneys are important in terms of high combustion efficiency low heating cost and protection of the environment...

Страница 12: ...el may be preferred In order to prevent condensation thermal insulation should be applied to the space between the inner and outer surfaces of the chimney At the lowest level of the chimney there must...

Страница 13: ...rs to circulate the water and circulate the smoke As the smoke passes between them it releases its energy and heats the water inside 3 Water grid They are the pipes for burning Water passes through th...

Страница 14: ...safety due to heating in the boiler 14 Safety return line It is the line where the water sent to the expansion tank is taken back to ensure safety from the boiler 15 Chimney hood It is the boiler sec...

Страница 15: ...31 33 33 35 35 40 Temperature Control Range o C 40 90 Return Temperature Recommended o C 40 Maximum Operating Pressure bar 3 Test Pressure bar 5 Dimensions Boiler Width A mm 1090 1185 1272 Depth B mm...

Страница 16: ...er to prevent the pump shaft from pressing the housing or the outer cover during operation Expansion tank In hot water heating systems when the water is heated from 10 C to 90 C its volume increases b...

Страница 17: ...boilers must be connected to an installation with an open expansion tank in accordance with the installation scheme shown below The circulation pump can be connected on the flow or return line In case...

Страница 18: ...essary measures are taken after the first filling there is no damage caused by the oxygen in the water Oxidation is mostly caused by oxygen which is involved in the heating water during operation The...

Страница 19: ...nstallation Considerations for heating connected to old installations A long term heating system produces a protective layer black magnetite on metal surfaces in contact with water When a new boiler i...

Страница 20: ...on Used to open and close the control panel button Used to input new value to the device Fan Adjustment Temperature Adjustment Fuel Feeding Fuel Standing ENTER Used to store set values and to access s...

Страница 21: ...e of the boiler is switched on and off with this button Fan On Off The fan of the boiler is switched on and off with this button Manual Fuel Feed It is used to load manual manual fuel into the boiler...

Страница 22: ...s and HEATING is not seen because the buttons are not pressed and the boiler does not work Open the boiler lower cover and hold the finger on the Manual Fuel Feed button on the control panel to allow...

Страница 23: ...r right side of the control panel will illuminate and HEAT will appear on the display If the ignition aids in the boiler ignite the fuel press the Reducer On Off button to switch on the gear unit The...

Страница 24: ...oal type can burn in an automatic combustion pot By changing the supplied feeding and waiting settings for this you can catch the most suitable burning setting for the boiler When there is no coal in...

Страница 25: ...cleaned Check that the fan is working properly Unbalanced balanced fan makes periodic noises If there are dust or ash collected between the fins of the fan it is necessary to clean it by blowing it wi...

Страница 26: ...l reservoir hopper Check that there are no holes or cracks in the chimney If you still can t consult your leg Have your chimney sealed Excessive fuel consumption Poor use of fuel may be High chimney t...

Страница 27: ...astic cover on the back of the control panel Activate the limit thermostat by pressing the red pin Turn the control panel off and on Panel over fuel warning is on Fuel in hopper The probe may be displ...

Отзывы: