TVD6.2-400-x-RS
39
Speed control switching
- two 16 pole binary switches S4, S5
- amplification trimmer P3 (Xp)
- D-component with jumper S14
- in case of exchanging the devices>>> take over adjustment values.
Default setup
- binary switch S4 und S5 on position 4
- amplification trimmer Xp on 50%
- no D-component, jumper S14 open
- optimal for most drives.
Caution:
with the input INTAB (X2:31) the I-component can be switched off.
Adjustment P-component with the binary switch
S4
switch S4
position 0
1
2
3
4
5
6
7
R-value 1000 450 280 209 180 148 123107 k
W
position 8
9
A
B
C
D
E
F
R-value 90 82 73 67 64 59 55
52 k
W
adjustment I-component with the binary switch S5
switch S5
position 0
1
2
3
4
5
6
7
C-value 0,01 0,02 0,03 0,04 0,08 0,09 0,1 0,11
m
F
position 8
9
A
B
C
D
E
F
C-value 0,11 0,12 0,13 0,14 0,18 0,19 0,2 0,21
m
F
Sp
ee
d
5 Adjustment
Содержание TVD6.2-RS
Страница 29: ...TVD6 2 400 x RS 29 Resolver 4 Device Overview ...
Страница 30: ...Transistor Servo Drive TVD6 2 RS 30 Componet Position ...
Страница 31: ...TVD6 2 400 x RS 31 Block Diagram 4 Device Overview ...
Страница 46: ...Transistor Servo Drive TVD6 2 RS 46 Connector X4 ...
Страница 47: ...TVD6 2 400 x RS 47 Encoder Signals Motor voltage Resolver Signals Motor current 7 Fault Finding ...