Transistor-Servo-Drive TVD6.2-RS
42
Default setup
check connections before putting into operation
- mains connection
clamps X3:3, X3:4, X3:5
max. 460V~
- protective conductor
earth screw at case
- motor connection clamps X3:7, X3:8, X3:9
- motor earth connection
clamps X3:6
- option
- external ballast resistor
clamps X3:1 and X3:2
mind connection advices on page 12.
Encoder connection X7
pay attention to the motor specific
connection sheets. See appendix A
Basic connections-supply lines
- protective conductor
- mains
1x oder 3x 400V~
- motor
3x mot earth con screen
- encoder
pay attention to the motor specific
connection sheets.
Basic connections - control lines
enable
contact betweem X1:1 and X1:2
nominal value
signal X1:4, GND X1:8
limit switch
limit switch at X1:16 and X2:32
or bridge X2:27 to X1:16, X2:32
Default adjustment for first putting into operation
switch
S4
P-amplification
position 4
switch
S5
I-component
position 4
potentiometer
I
max1
peak current
10%
potentiometer
I
max2
peak current
10%
potentiometer
I
D
steady current
100%
potentiometer
Xp
amplification
50%
potentiometer
INT
integrator
anti-clockwise stroke
potentiometer
n
max
speed
anti-clockwise stroke
Jumper
unplugged
plugged
S2, S14, S18
J1, J2, J3, J4
S3, S6, S11, S12, S19, S20
SW1 Pos.1-2
SW1 Pos.2-3
SW2 Pos.1-2
SW2 Pos.2-3
G
et
tin
g
St
a
rte
d
Содержание TVD6.2-RS
Страница 29: ...TVD6 2 400 x RS 29 Resolver 4 Device Overview ...
Страница 30: ...Transistor Servo Drive TVD6 2 RS 30 Componet Position ...
Страница 31: ...TVD6 2 400 x RS 31 Block Diagram 4 Device Overview ...
Страница 46: ...Transistor Servo Drive TVD6 2 RS 46 Connector X4 ...
Страница 47: ...TVD6 2 400 x RS 47 Encoder Signals Motor voltage Resolver Signals Motor current 7 Fault Finding ...