Transistor-Servo-Drive TVD6.2-RS
44
All LED dark
No mains V0ltage
fuse on power supply unit blown
out
LED D1A dark
LED D2A bright
Check power supply unit
LED D1A dark
LED D2A dark
LED D2B bright
LED D2F bright
LED D2G bright
internal or external
power supply
overloaded
short or line-to-earth fault in
motor line
or outputstage error
heatsink-temperature >80°C
connect limit switches
LED D1G dark
LED D1H dark
check limit switches or
bridge limit
switches
connect enable
check enable voltage
and jumpers
LED D1B dark
preset nom.v alue ±
LED D1C dark
LED D1D dark
motor mech. blocked
motor- or encoder line wrong
LED D1F bright
check nom.value
and jumper
let device be checked
by the manufactorer
Switch on mais
Fa
u
lt
Fin
d
in
g
let device be checked
by the manufactorer
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
no
no
no
no
no
no