TVD6.2-400-x-RS
25
Signal output
logical outputs with opto-coupler
- wire break secure
in case of error output is locked
- output voltage
10 ... 30V=
- output voltage
5mA
- output resistance
1k
W
Overview of signal outputs
signal
function
output
indication stored
intermediate
power supply
circuit
unit error
X1:14
LED 2A
yes
overload
blocked
X2:18
LED 1F
no
standstill
speed
< 1%
X2:25
LED 1E
no
overtemperature
motor
>150°C X2:26
—
no
heat sink
> 75°C
X2:26
—
no
heat sink
> 80°C
X2:26
LED 2G
yes
warning
motor, heat sink
too hot
X2:19
—
no
reference earth
GND
X2:23
memory reset:
enable
off/on
jumper
S6
plugged (
default setup
)
main
s
off/o
n
jum-
per
S6
un-
plug-
ged
Si
g
n
a
ls
3 Electrical Installation